Power And Gain - CPI 0102324500rR Manual

Table of Contents

Advertisement

CHPA S
ERIES

6.8 Power and Gain

Follow these steps to test the HPA power and gain. Record the results on the chart provided in
Table 6-3.
1. Connect the equipment as shown in Figure 6-1.
2. Set the input drive level to minimum and the HPA gain to maximum.
3. Set the sweeper to CW to the frequencies selected. These will be used every time preventive
maintenance is performed so that a trend can be developed.
4. Increase the drive level until the HPA has reached saturation. Record level on the test data
sheet.
5. Reduce the drive level until HPA is at the rated power output (if the result of step 4 is
greater than the rated power output).
6. Calculate the gain and record the results on the test data sheet. Gain = Po (dBm)–Pi (dBm).
7. Reduce drive level until HPA is at rated power -10 dB. It may be necessary to use a 10 dB
fixed attenuator at the HPA input to achieve a reliable input power measurement.
8. Calculate the gain and record the result on the test data sheet.
9. Repeat for all required frequencies.
6-8