Factory Tests; Reset Elapsed Time Meters; Reset To Factory Defaults; Chpa Hvps Test Mode - CPI 0102324500rR Manual

Table of Contents

Advertisement

CHPA S
ERIES
B.13.4 Factory Tests
(This category appears only during FAAM.)
This category is used for factory testing and is not for customer use. Unauthorized use of this
mode could cause damage to the unit.
B.13.5 Reset Elapsed Time Meters
(This category will appear only during FAAM.)
Data entry (separate entry for each item listed):
Heater Elapsed Time Meter Reset
Beam On Elapsed Time Meter Reset
Key sequence for accepting entries is: SPECIAL, SPECIAL, ENTER, ENTER.
B.13.6 Reset to Factory Defaults
Reset to Defaults allows the user to reset all parameters (fault settings, etc.) to firmware
defaults. Settings not affected by this command are: Helix Avg. Over Current Fault, Helix Over
Voltage Fault, Helix Under Voltage Fault, Beam On Elapsed Time meter, and Heater Elapsed
Time Meter.
B.13.7 CHPA HVPS Test Mode
(This category will appear only during FAAM and unit in Standby.)
This test mode allows the power supply to be tested with a special test jig. In this mode, Helix
Under Voltage Fault, Helix Voltage Detected in Standby, and TWT Thermal Fault are masked in
the Transmit state. This test mode may only be selected from the Local panel while the CHPA is
in the Standby state. If the CHPA prime power is lost while HVPS TEST=YES, the CHPA will
power up with no Beam Select and HVPS TEST=NO.
Lines 3 and 4 will appear as follows:
H V
P S
T E S T
H V
P S
T E S T : N O
To select this test mode, press either arrow key to select YES on Line 4. In this test mode, any
meter may be selected. All other CHPA features and controls (aside from the STANDBY and
TRANSMIT button) will be inactive. If a fault occurs, the HVPS TEST will be turned off.
B-18
M O D E
THIS DOCUMENT IS THE PROPERTY OF COMMUNICATIONS & POWER INDUSTRIES.
REPRODUCTION OR RELEASE WITHOUT EXPRESS PERMISSION IS STRICTLY PROHIBITED
D
.01023245 R
.R
OC
EV