User Tests; Table B-7. User Tests And Results - CPI 0102324500rR Manual

Table of Contents

Advertisement

When Line 4 indicates YES, press the TRANSMIT button to turn the beam on. Provided no fault
occurs, Lines 1 and 2 will appear as follows (Lines 3 and 4 will display the selected meters):
L O C A L
B E A M
O N
Once the Beam On Sequence is complete, Line 2 will display the following:
H I G H
V O L T A G E
To exit this test mode, return to the HVPS TEST MODE menu. Use the arrow keys to choose
NO. The display (Lines 3 and 4) will return to the following:
H V
P S
T E S T
H V
P S
T E S T : N O
B.13.8 User Tests
User Tests includes miscellaneous hardware tests available to the user. See Table B-7.

Table B-7. User Tests and Results

Function Name
Lamp Test
Beeper
Aux Serial Port back
test
Line 3 will indicate:
U S E R
T E S T
Line 4 will indicate (in order):
L A M P
T E S T : E N T E R
If a test is performed, the result (as described above) will be reported in place of ENTER.
B E E P E R : E N A B L E
A U X
L O O P
D
.01023245 R
.R
OC
EV
S E Q U E N C E
M O D E
Possible Entries/Results
Press ENTER to perform test. No
result is reported.
Use arrow keys to enable or
disable beeper.
B A C K : E N T E R
THIS DOCUMENT IS THE PROPERTY OF COMMUNICATIONS & POWER INDUSTRIES.
REPRODUCTION OR RELEASE WITHOUT EXPRESS PERMISSION IS STRICTLY PROHIBITED
P S T
O N
P S T
Description
Illuminates all luminescent devices on the
panel for 15 seconds.
Press ENTER to start (same as other 2
loopback tests.)
Press ENTER to start; will display Loop
PASS if unit sees itself, FAIL if it doesn't.
Press ENTER again or leave this item to
stop the test. For the unit to see itself, loop
TX+ to RX+ and TX- to RX- (if using RS-
422/485) or TX to RX (if using RS-232)
CHPA S
ERIES
5 : 2 7 A
T
B-19

Advertisement

Table of Contents
loading

Table of Contents