Instead, if you want a double espresso using pourer B3, you have to press key 6 of the right pushbutton
panel. Once pressed one of the pouring keys, you need to wait three seconds for the coffee to start
pouring. Once reached the programmed level, the pouring of the coffee stops automatically. If you want
to stop the pouring sooner, just press the pouring key again. Once the coffee has been poured, we
recommend removing the pod to prevent it from sticking when it dries.
It is important to empty the drip tray (ref. A) after the pouring of not more than 50 cups of coffee.
The machine was calibrated in the plant with an appropriate electronic programming of the doses,
which keeps into account the pressing of the specific grinding of the pods distributed by your Supplier.
However, it is possible to customise and modify all the preset coffee quantities in the following way:
Keep key 7 pressed until the LED starts blinking (from this moment the programming must be executed
within 30 seconds). To programme ALL the "single espressos" made by the machine, press the 0 key (left
pushbutton panel) to start the pouring of the coffee and press it again once reached the desired dose.
To programme ALL the "long espressos" made by the machine, press the 1 key (left pushbutton panel) to
start the pouring of the coffee and press it again once reached the desired dose. To confirm and exit the
programming mode, press key 7 again (all the LEDs become fixed).
Only after having executed the above-mentioned procedure, it is possible to differentiate the coffee
quantities of every single pourer in the following way: Keep key 7 pressed (right pushbutton panel) until
it starts blinking. Press the pourer key that you want to programme (of any of the two pushbutton panels
ref. D) to start pouring the coffee and press it again once reached the desired dose. Repeat the same
procedure for every pourer key for which you want to programme the dose. To confirm and exit, press key
7 again.
Exclusively use the pods of your Supplier. The use of pods different from those
for which the machine was conceived may not guarantee the same pouring
quality.
If the tray is not emptied, the water can overflow.