Connecting Quick Release Couplings
1
Remove any residual hydraulic pressure trapped in
the service line hose.
2
Wipe the two faces of the male and female couplings
and make sure they are clean.
3
Make sure that ball C in the female coupling is located
in one of its slots.
4
Fit the male coupling into the female coupling.
5
Where applicable, rotate sleeve E half a turn and
make sure that the locking ball C does not align with
the slot D.
Disconnecting Quick Release Couplings
1
Remove any residual hydraulic pressure trapped in
the service line hose.
2
Where applicable, align the slot D with ball C.
3
Pull back sleeve E to release the coupling.
Fig 133.
168
Connecting/Disconnecting Hydraulic Hoses
C007100-1
9811/5700-7
Optional Attachments