ELECTRIC CONNECTION

 Before making the connection, verify that the electric wiring
prepared by the customer follows the current regulations and
that it has been earted according to regulations. Remember
that Gruppo Cimbali Spa is not responsible for damages due
to incorrect electrical connections and, furthermore, that the
installer is responsible in case of damage.
 Besides the above, check:
- the type of connection and the voltage must correspond to
those indicated on the nameplate data.
For more information, please consult the specific electric
diagrams.
Technical data See the machine's nameplate
nOISE The equipment does not exceed 70dB

POTENTIAL-EQUALIZING CONNECTION

This connection, which is the one called for by several norms,
avoids electrical potential differences building up between any
equipment that may be installed in the same room.
There is a terminal clip on the under side of the base of the
machine to which an external potential-equalizing wire should
be connected.
This connection is ABSOLUTELY NECESSARY and must be
made right after the machine is installed.
- Use a wire whose cross-sectional area conforms to the
existing norms.
- Make the terminal connection (see diagram) and then
connect the other end to the ground connections located
on the adjacent equipment.
Failure to do observe these safety precautions will exempt
the manufacturer from any responsibility as regards damage
caused to persons or property.
NOTE: DO NOT CONNECT THE MACHINE'S TERMINAL
CLIP TO THE MAINS GROUND TERMINAL BECAUSE
THE GROUND TERMINAL OF ANY MAIN SOURCE OF
ELECTRICAL POWER IS NOT CONSIDERED TO BE A
POTENTIAL-EQUALIZING CONNECTION.
Installation
Machines with single phase connection
N
White
T
Black
1
7
N
Blue
T
Brown
2