Advertisement

Quick Links

Quick Start Guide
SpeedFace - V5L[QR] Series
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between
the actual product and the written information in this manual.

Advertisement

Table of Contents
loading

Summary of Contents for ZKTeco SpeedFace V5L QR Series

  • Page 1 Quick Start Guide SpeedFace - V5L[QR] Series Version: 1.0 Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
  • Page 2 Overview SpeedFace-V5L[QR] Flash Camera & Palm Collector Microphone 5" Touchscreen QR Code Scanner Magnetic Tamper Switch Reset Speaker Auxiliary Input Power In RXD2 Sensor TXD2 RS232 Ethernet Exit Button +12V IWD0 RS232 Lock Wiegand IWD1 485A Wiegand RS485 Alarm 485B Note: Not all products have the function with , the real product shall prevail.
  • Page 3: Installation Environment

    Overview SpeedFace-V5L[QR][TD] SpeedFace-V5L[QR][TI] Thermal Infrared Temperature Thermal Imaging Temperature Measurement Module Detection Module Installation Environment Please refer to the following recommendations for installation. INSTALL INDOORS AVOID INSTALLATION AVOID DIRECT ONLY NEAR SUNLIGHT GLASS WINDOWS AND EXPOSURE AVOID USE OF ANY HEAT SOURCE NEAR THE DEVICE...
  • Page 4 Recommended Palm Gestures KEEP EFFECTIVE KEEP SPACES DO NOT KEEP DISTANCE OF BETWEEN YOUR FINGERS 30 to 50 cm YOUR FINGERS CLOSE DO NOT KEEP DO NOT KEEP PALM OUTSIDE YOUR FINGERS COLLECTION AREA FOLD/CURLED Note: 1. Place your palm within 30 to 50 cm of the device. 2.
  • Page 5 Installation Re uirements The installation requirements and indications associated with the device are given below: Specification Standard value Remark Indoor, Avoid wind, Avoid The recommended operating Operating direct sunlight, temperature is 25°C (77°F) Environment 16°C to 35°C (60.8°F to 95°F) Distance The recommended distance 30 to 120cm (0.98ft to 3.94ft)
  • Page 6: Device Installation

    Device Installation Take SpeedFace-V5L[QR][TI] as an example: ① 1.5m ② ① Attach the mounting template sticker to the wall, and drill holes according to the mounting paper. Fix the back plate on the wall using wall mounting screws. ② Attach the device to the back plate. ③...
  • Page 7 ower Connection Recommended power supply 1) 12V ± 10%, at least 00mA. 2) To share the power with other devices, use a power supply with higher current ratings. thernet Connection RJ 45 COMM. Ethernet IP Address , input the address and Note: n A , addresses o the server ) and the device must e in the...
  • Page 8: Lock Relay Connection

    oor ensor it utton larm Connection witch Lock Relay Connection The system supports both Normally Opened Lock and Normally Closed Lock. The NO Lock (normally opened when powered) is connected with 'NO1' and 'COM' terminals, and the NC Lock (normally closed when powered) is connected with 'NC1' and 'COM' terminals.
  • Page 9 Wiegand Reader Connection Wiegand card reader connects to the top 4 pins of the wiegand terminal and the last two pins are used by the Access controller, as shown in the following gure. It sends the credentials to the device via wiegand communication. +12V IWD0 IWD1...
  • Page 10: User Registration

    User Registration When there is no super administrator set in the device, click on to enter the menu. Add a new user and set User Role to Super Admin, then the system will request for the administrator’s veri cation before entering the menu. It is recommended to register a super administrator initially for security purposes.
  • Page 11 Method 2: Register on ZKBioSecurity software Please set the IP address and cloud service server address in the Comm. Menu option on the device. 1. Click [Access] > [Access Device] > [Device] > [Search Device] to search the device on the software. When an appropriate server address and port is set on the device, the searched devices are displayed automatically.
  • Page 12 Method 3: Register on the phone Once the ZKBioSecurity software is installed, the users could enroll their face via a browser application on their own mobile phone. 1. Click [Personnel] > [Parameters], input ‘’http://Server address: Port’’ in the QR Code UGL bar. The software will automatically generate a QR code. Scan the QR code or login onto ‘’http://Server address: Port/app/v1/adreg’’...
  • Page 13 Ethernet and Cloud Server Settings COMM. Ethernet Click on > [ ] > [ ] to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface. >...
  • Page 14: Access Control Setting

    Access Control Setting > [Access Control] Click on to enter the access control management interface and set relevant parameters of access control. Main Menu Access Control Options Access Control Access Control Options Gate Control Mode User Mgt. System User Role COMM.
  • Page 15 Detection Management Settings System Detection Management Click on > [ ] > [ ] to enter the setting interface You can set the value of High temperature alarm threshold, and enable the Temperature over the range; access denied and the Trigger external alarm, the device will send an alarm prompt when the temperature of the user detected exceeds this value, meanwhile the user will be forbidden to access, as shown in the following gure.
  • Page 16 Notes: The e ective distance for temperature detection is within 50cm. Recommended for indoor use. Temperature measurement data is for reference only, not for medical use. Remove the mask to register the face, wear a mask to recognize the face, the type of mask, the size of the face covered by the mask, and bangs will a ect the facial recog- nition e ect.
  • Page 17 Real-Time Monitoring Welcome, admin 2020-05-28 11:03:07 Real-Time Monitoring Temperature Real-Time Monitoring Total: Statistics Panel Normal Records Abnormal Temperature Temperature Raw Record Personnel Temperature Schedule Abnormal T emperature Name: UnregisterUser Record Departmental body Department: NULL temperature daily statistics report Temperature: 36.57° Parameters Mask: Monthly Event Statistics...
  • Page 18 QR Code Verification On the Server, choose [System] > [Authority Management] > [Client Register] to add a registered App client. Open the APP, enter the IP address or domain name of the server, and its port number, scan the QR Code of the new APP client. After the connection is successful, tap on Employee to switch to Employee Login screen.
  • Page 19 ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 - 82109991 : +86 755 - 89602394 www.zkteco.com Copyright © 2021 ZKTECO CO., LTD. All Rights Reserved.