Working with the main menu
BOSCH
The following table shows you how to adapt the settings for DHW
circulation.
~
If the standard display
is
active. press the menu key briefly to open or
close
the main
menu
.
Turn the selector to highlight DHW and press the
selector.
Turn the selector to highlight Circulation
and
press the
selector.
The
Operating
mode menu
item
is highlighted.
~
Press the
selector.
~
Turn the selector to highlight
As hot water system
and
press the
selector.
6720
811 136-29.10
The user
interface
operates with the modified
settings.
The DHW circulation pump
is
only
in
operation when DHW heating
is
active.
,
~
Turn the
selector
to highlight
Own
time
program
and
press the
selector.
The time program for
circulation
is independent of the time program for DHW heating.
The switching times
can
be
set separately
in the
Circulation
>
My DHW
cireltn
time
Mon·Frl
copy
prog.
menu (operation
as
described
in Chapter 5.2.2 starting on
page 16). The
~om
05:00
c:oo=J
8
,
.,~.""
i'.tho,,,,,,,,,,,
",,,,ft
i"
""_"_'"".
~
.'
6720815
I
~
Turn
the
selector to highlight
off
or on and press the
selector.
The
user
interface
operates with the modified
settings.
The DHW
circulation
pump is
~
ways
off
in
the phases with
off.
Table
24
Adapting
circulation
settings
5.4
Settings for a heated swimming
pool
This menu is used to adapt the settings that are available for
a
heated
swimming
pool.
Menu:
Pool
Menu item
description
Activate
pool
The sWimming pool
IS
heated when the pool
I
heating
__
_
-lheating
system
is
switched
on.
~
,Pool
The water
in
the swimming pool is heated to
temperature
I
the temperature set
here.
r
Allow
If the
auxiliary
heater has been
approved
for
I
additional
use with the
swimming
pool.
the required
heat in pool
water temperature can
also
be
reached
mode
using the auxiliary heater even
if
the heat
pump does not supply enough heat.
Table
25
Swimming pool
settings
5.5
Additional device
(auxiliary heater) settings
If the heat pump does not
supply
enough heat quickly enough in
winter or for DHW heating. an additional device
(an auxiliary
heater) may be required
.
There
is
the option to use
an
electric
booster heater
or an additional
device
(gas. oil or
wood heating
via
a
3·way
valve)
.
This menu
is
only available if an
auxiliary
heater
is
installed in
the
heating
system.
5.5.1 Time
program for the
additional
device
If you are not at home or a lower room temperature
is sufficient
for other
reasons.
it
is
possible to lower energy
consumption
by
limiting the operation of the auxiliary heater
Menu:
Device
>
Time program additional
heat
Time
I
program
Activate
additional
heat
My
time
program
Reset
time
,
program
,Time
program
I
min.
outdoor
~emp.
When the time program for the auxiliary heater
has been activated. the auxiliary heater
is only
I
able
to deliver additional heat
in
the phases with
I
I
the on
operating
mode.
The time program for the auxiliary heater
can
be
set
under this menu
item.
The time program for the auxiliary heater
is
reset
to the default
settings.
If the outside temperature
fa
- ::
lls
"
"b
" "
e
""
l
o- w-
th
" "
e
-~
temperature set here. the
auxiliary
heater
time
,
program
is switched
off.
The
auxiliary
heater is
in
operation.
Table 26
Time
program for an additional device
24
HPC
400 - 672082198312017/07)
@
BOSCH
5.6
Setting
up a holiday program
Menu:
Holiday
If you leave the house for several days or
if
you have several
days' holiday. you can setthe holiday program. Ifthe heat pump
is in heating mode according to the settings for summer!
wintertime changeover. the holiday functions are
used.
Thus
you heat particularly economically for the duration of the
holiday program or with a time program like
"as
Saturdays' or
you do not heat at all.
[ ]
Regardless of the settings you make for the
1
holiday
program.
cooling mode will not be
activated during your
holiday.
You can optionally switch off DHW heating completely for the
duration
of your
holiday.
The factory settings ensure energy
efficremand reliable operation during your
holiday.
Duringthe
holiday
period.
the display
indicates
when the holiday program
will be active until.
Fr 21 03,2014
lHS
4o.S·
C
10
12.5'0
Flow t.mperaturt
He1
Holld_
unto
23.3,201.
--
- -
·CO+.O~
6720612 n5-3110
Fig.
4
Standard display during holiday period
The time programs that would ordinarily apply are not changed
by the settings or the use of the holiday
program.
After the end
of the holiday program. the user interface works again with the
set time
program.
The holiday program is deleted automatically
when it reaches its end.
&
NOTICE:
Damage to the
system.
I
~
If you are going to
be
away for a long time
you
should
only
change
the
settings
in the
menu option
Holiday.
~
After a long period away the operating
pressure should be
checked
with pressure
gauge for the heating system and where
necessary solar panel
system.
~
The solar heating system
should
not be
switched
off.
even if you are away for a
longtime.
Working with the main menu
A detailed description of how you can set the holiday program
can be found in
Tab.
28. slartingon page
26.
Menu:
Holiday
1.
Holiday 2, Holiday
3.
Holiday 4
and
Holiday
5
I
Menu item
description
Holiday
period
Selection
helt.
eire.,
DHW
DHW
Delete
Set the start and end date of the absence
during
holiday:
The holiday program is
started at the set beginning at
00:00.
The
holiday program is terminated at the
set
end
at
24:00.
I
The holiday program
is
applied to the
I
sections of the system highlighted
here.
Only the heating/cooling circuits and the
DHW system actually installed
in
the system
are listed for
selection.
Control of the room temperature for the
selected heating circuits during the holiday
period:
I
.
With
As
Saturday.
the heating system
runs in the selected heating circuits
every day in accordance with the time
program that is active for Saturday
(holiday at home)
.
A
Constant temperature
can be
selected at will to be valid for the entire
holiday period for the selected heating
circuits.
The
Off
setting deactivates the heating
system
completely
for the selected
heating
circuits.
DHW settings during the holiday
period.
If
Off
is
set.
no DHW at all will be available
during the holiday
period.
If
Off
+ thermo disinfection on
is set.
DHW heating
is
deactivated but thermal
I
disinfection is still carried out as normal
either once
a
week oronce a
day.
If you
are
spending your holiday at home. the
DHW system must not be selected under
Selection heat.
eirc.!DHW.
so
as
to ensure
that DHW remains
available.
i
Delete all settings for the
sel-
e c -te
-
d ""h -o
"-
lid
"-
a
-y---!
,
program
Table
27
Settings forho/iday programs
The following table shows you how to set up a holiday
program.
interrupt
a holiday program that is
active
and delete a holiday
program.