General Specifications (continued)
RF Field Specification
Safety
EMC
Certifications
Resolution and Accuracy
Function
K
L
?
e
Input Characteristics
Function
K
L
e
e
CAT III protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in
large buildings.
CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility
service.
Serial Numbers 79559999 and Below
General Specifications
Calibration
Maximum Voltage
Between any Terminal
and Earth Ground
Temperature
Altitude
Relative Humidity
Battery Type and Life
1.800.561.8187
0.5 % full scale + (specified accuracy) at 3 V/m
Complies with ANSI/ISA-S82.01-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1-
92, and EN61010-1 1995.
EN 61326
T5-600 Range
T5-1000 Range
600 V rms
1000 V rms
600 V
1000 V
100.0 A
100.0 A
1000 Ω
1000 Ω
Input Protection
T5-600
T5-1000
600 V rms
600 V rms
600 V rms
Open Circuit Test Voltage
1.65 V dc (nominal)
One-year calibration cycle.
T5-600: 600 V rms, Overvoltage Category III
T5-1000: 1000 V rms, Overvoltage Category III
Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)
Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)
0 % to 95 %, 5 °C to 30 °C (41 °F to 86°F); 0 % to 75 %, 30 °C to 40 °C (86 °F to 104 °F);
0 % to 45 %, 40 °C to 50 °C (104 °F to 122 °F)
AA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride
www.
In accordance with IEC 61010-1 54CJ
Resolution
1 V
1 V
0.1 A
1 Ω
1000 V rms
1 MΩ, <100 pF ac-coupled
1000 V rms
1 MΩ, <100 pF
1000 V rms
.com
Service Information
Serial Numbers 79559999 and Below
Accuracy
±(1.5 % + 2 digits)
±(1 % + 1 digit)
±(3 % + 3 digits)
±(1 % + 2 digits)
Input impedance (nomial
Short Circuit Current
<600 µA