  • Page 1  52PRO Test Set Users Guide PN 3394309 January 2009 Rev. 5, 5/2018 ©2009-2018 Fluke Corporation All product names are trademarks of their respective companies.
  • Page 2 The warranty extends only to the original buyer or end user customer of a Fluke Networks authorized reseller, and does not apply to any product which, in Fluke Networks’ opinion, has been misused, abused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling.
  • Page 3: Table Of Contents

    Contents Title Page Introduction ................................1 Registration .................................1 Contacting Fluke Networks ..........................1 Symbols ................................1 Safety Information ............................2 Product Features ..............................2 Physical Characteristics ............................3 Housing ................................3 Belt Clips ...............................3 Line Cords ..............................4 Battery ................................4 Speaker and Speakerphone Microphone ....................4 Audio Controls .............................4 Display and Keypad .............................6...
  • Page 4 TS52PRO Test Set Users Guide Configuring Your Test Set .........................13 Last Number Redial ..........................14 Program Speed Dialing Numbers .......................14 Putting a Pause in a Stored Number ....................14 Storing the Last Number Dialed ......................14 Storing a Number You are Calling .....................14 Dialing a Stored Number ........................15 Hook Flash Duration ...........................15 Make Receive-Only Loud Speaker the Default .................15...
  • Page 5: Introduction

    The test set has a speaker for hands-free listening. The test set also has a Fluke Networks operates in more than 50 countries speakerphone that allows two way conversations while worldwide. For more contact information, go to freeing up the operator’s hands for other tasks.
  • Page 6: Wsafety Information

    TS52PRO Test Set Users Guide  Do not use the test set if it is damaged. Before 40 year Environment Friendly Use Period  you use the test set, inspect the case. Look for (EFUP) under China Regulation - cracks or missing plastic. Pay particular attention Administrative Measure on the Control of to the insulation surrounding the connectors.
  • Page 7: Physical Characteristics

    Physical Characteristics Physical Characteristics Belt Clips See Figure 1. Housing The belt clip can be located at either or both ends of the housing. It has a spring-loaded, locking clip that See Figure 1. assures a secure connection to belt loops and D-rings. Both forward folding and backwards folding versions The TS52PRO Test Set housing is made of high-impact of the belt clip may be installed.
  • Page 8: Line Cords

    If it still The test set has a field replaceable line cord. The line does not work, contact Fluke Networks Technical cord is attached through a rubber strain relief at the Support.
  • Page 9 Physical Characteristics Handset receiver Handset microphone Mute key Speaker key Volume key bfp02.eps Figure 2. Audio Control Keys Table 1. Test Set Audio Control Keys Description (refer to Figure 2) The MUTE key functions only when the test set is off-hook. When the test set is off-hook and being MUTE used as a handset, pressing the MUTE key shuts off the handset’s microphone.
  • Page 10: Display And Keypad

    TS52PRO Test Set Users Guide Table 1. Test Set Audio Control Keys (continued) Description (refer to Figure 2) Pressing the VOL key switches the active receiver’s sound level between normal and high volume. (Volume) This occurs in Monitor mode and Talk mode. The state of the VOL key is preserved when the active receiver is changed.
  • Page 11 Physical Characteristics Table 2. Display and Keypad Key or Indicator Description (refer to Figure 3) Numeric The numeric keypad is used to dial telephone numbers and make function selections. The  Keypad numeric keypad includes 12 standard dialing keys including the star ( ) and the pound (#) keys.
  • Page 12 TS52PRO Test Set Users Guide Table 2. Display and Keypad (continued) Key or Indicator Description (refer to Figure 3) When you press the Vdc/mA TEST key, one of two tests is performed depending on the Vdc/mA TEST operating mode of the test set. If the test set is in Monitor mode and you press the Vdc/mA TEST key, the Vdc (dc voltage) test will be executed.
  • Page 13 Physical Characteristics Table 2. Display and Keypad (continued) Key or Indicator Description (refer to Figure 3) Speaker icon Pressing the SPKR key switches the speaker on and off. The speaker icon indicates the status. The speaker icon is shown when the speaker is on. The absence of the icon indicates that the speaker is off.
  • Page 14: Operation

    TS52PRO Test Set Users Guide Table 4. TS52PRO Timeout Defaults Monitor Mode/Talk Mode (On-hook)** Talk Mode (Off-hook) 30 seconds Always on SPKR Mode 2 minutes 240 minutes Handset Mode 2 minutes Always on ** Monitor Mode Only - You can monitor a line for 2 minutes. Although the LCD will turn off after 30 seconds, the test set is still on. You can monitor the line for an additional 90 seconds after the LCD turns off.
  • Page 15: Caller Id

    Operation In the Monitor mode, the test set is typically used for If the line is idle, set the Talk/Monitor switch to T. one or more of the following procedures: The test set automatically tests for high-speed data and talk battery on the line. ...
  • Page 16: Ground Start

    TS52PRO Test Set Users Guide Ground Start Data Safe Practices Always monitor the line for an audible signal before Ground start lines are typically found on PBX attempting to go off-hook to draw dial tone. The data installations. To activate an idle ground start telephone detect circuitry on the test set is designed to detect line, do the following: data signals above the human audio range.
  • Page 17: Data Lockout Override Operation

    Operation It is best to put the test set in Monitor mode when High Voltage Lockout Operation troubleshooting a line, searching for capacitance kicks, RF signals, craft provided tones, etc. Warning If the voltage on the line is above 140 V dc, Data Lockout Override Operation this is potentially dangerous to you and the test set.
  • Page 18: Last Number Redial

    TS52PRO Test Set Users Guide Last Number Redial Putting a Pause in a Stored Number To redial in tone dialing mode, go off-hook and press Note the LNR key. To redial in pulse dialing mode, go off- Each time the PAUSE key is pressed, it counts as hook, press the TONE/PULSE key, then press the LNR one dialing digit.
  • Page 19: Dialing A Stored Number

    Operation Dialing a Stored Number Make Receive-Only Loud Speaker the Default Connect the test set to a working telephone line. On a TS52PRO fresh from the factory, if you take the unit off-hook and press the SPKR key, the Speaker- Set the Talk/Monitor switch to T.
  • Page 20: Speaker/Lcd/Test Set Timeout

    TS52PRO Test Set Users Guide Speaker/LCD/Test Set Timeout LCD Backlight The speaker uses a lot of battery power. The battery You can conserve the test set battery life by keeping drains quickly when the speaker is left on continuously. the display backlight off when it is not needed. The To extend battery life, the test set has a timeout default state of the backlight is off.
  • Page 21: Factory Defaults

    Maintenance After you dial the ANAC number and get a response, Maintenance the phone number of the line pair that the test set is connected to is shown on the display. If the ANAC Warning response is greater than 10 digits, the last 10 will be displayed.
  • Page 22: Replacing Or Relocating The Belt Clip

    Use a Phillips screwdriver to loosen only the four to one of two locations. To order a replacement belt screws attaching the battery door cover to the clip, contact your local Fluke Networks authorized back of the test set. Remove the battery door distributor.
  • Page 23: Replacing The Line Cord

    Slip the line cord screw lugs (Figure 8) out through the user. To obtain a replacement line cord, contact the hole in the end of the housing. your local Fluke Networks authorized distributor. Warning Read all instructions completely and understand possible hazards to end user if repairs are not performed properly.
  • Page 24: Installing A New Line Cord

    TS52PRO Test Set Users Guide Insert the plastic clip over the line cord strain relief at the base of the test set housing (Figure 7) and press tightly into place. Inspect all work to ensure no pinched wires or areas where weather resistance and safe operation is affected.
  • Page 25: Accessories (How To Order)

    Maintenance Accessories (How to Order) To order accessories, contact your local Fluke Networks distributor. Description Model Number Belt clip, lockable (both ends) P4080248 Belt clip, non-lockable (both P4080249 ends) Standard Line Cord with Piercing P4480001 Pin Clips Central Office Line Cord with...
  • Page 26: Specifications

    TS52PRO Test Set Users Guide Specifications Physical Measurement 10 in x 3.75 in x 4.25 in Electrical (254 mm x 96 mm x 107 mm) Current Range 10 mA to 100 mA Weight Less than 1.5 pounds (0.68 kg) (Off-Hook) with one belt clip DC Resistance Water Resistance...