Fluke T5-600 Service Information

Fluke T5-600 Service Information

Electrical tester
Hide thumbs Also See for T5-600:

Advertisement

Quick Links

Introduction
This service information sheet provides the following information for the T5-600 and T5-1000 Electrical
Testers (hereafter referred to as "the tester").
Safety information
Parts and service information
Specifications
Cleaning procedure
Required equipment
Performance tests
Parts and accessories list
Battery replacement procedure
For operating instructions, refer to the T5-600/T5-1000 Electrical Tester Instruction Sheet.
Safety Information
To avoid possible electric shock or personal injury, follow these guidelines:
Do not use the tester if it is damaged or operating abnormally. Protection
may be impaired.
Before each use:
Make sure the battery door is closed and latched.
Inspect the tester and test leads. Look for cracks, missing plastic, exposed
metal, or damaged insulation. Replace damaged test leads before using the
tester.
Verify the tester's operation by measuring a known voltage.
Replace the batteries as soon as the low battery indicator (M) appears.
Do not use the tester around explosive gas, vapor or dust.
Do not apply more than the rated voltage, as marked on the tester, between
terminals or between any terminal and earth ground.
Refer servicing to qualified personnel.
Use caution when working above 30 V ac rms, 42 V ac peak, or 60 V dc.
When using the probes, keep your fingers behind the finger guards on the
probes.
Connect the common test lead before you connect the live test lead.
Disconnect the live test lead first.
The display will not display hazardous voltages in display hold. The voltage
indicator LED (
PN 686953
March 1998 Rev.1, 9/01
 1998-2001 Fluke Corporation. All rights reserved. Printed in U.S.A. Product names are trademarks of their respective companies.
Shop for Fluke products online at:
Warning
) continues to operate.
MyFlukeStore
www.
T5-600/T5-1000
Electrical Tester
Service Information
1.800.561.8187
.ca
®

Advertisement

Table of Contents
loading

Summary of Contents for Fluke T5-600

  • Page 1 LED ( ) continues to operate. PN 686953 March 1998 Rev.1, 9/01  1998-2001 Fluke Corporation. All rights reserved. Printed in U.S.A. Product names are trademarks of their respective companies. MyFlukeStore 1.800.561.8187 www. Shop for Fluke products online at:...
  • Page 2: Parts And Service

    Earth Ground Pollution Degree 2 Maximum Voltage T5-600 and T5-1000: 1000 V rms, Overvoltage Catergory III, also 600 V rms, Overvoltage Between Current Fork Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.) and Earth Ground Operating: -10 °C to +50 °C (14 °F to 122 °F);...
  • Page 3: Resolution And Accuracy

    General Specifications Calibration One-year calibration cycle. Maximum Voltage T5-600: 600 V rms, Overvoltage Category III Between any Terminal T5-1000: 1000 V rms, Overvoltage Category III and Earth Ground Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)
  • Page 4: Cleaning The Tester

    Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum) Surge Protection T5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09 Enclosure Rating IP 52 per IEC 60529, no vacuum applied RF Field Specification 0.5 % full scale + (specified accuracy) at 3 V/m...
  • Page 5: Performance Tests

    Equipment Required for Performance Tests Equipment Required for Performance Tests The following equipment is required for performance tests: • Fluke 5500A Multi-Product Calibrator, or equivalent • 0 V to 5 V adjustable dc power supply • Approximately 8 m (26 ft) of #14 single-conductor magnet wire wound into a butterfly-shaped coil.
  • Page 6 Separate into two 5-turn coils. 21 cm (~8.25") Use cable ties to hold coils together Mount Banana plugs on wire end Connect to Calibrator qp7f.eps Figure 1. Making the Butterfly Coil MyFlukeStore 1.800.561.8187 www. Shop for Fluke products online at:...
  • Page 7 Correct operation of the HOLD function Perform the tests as follows: 1. Set the calibrator to the T5-600 or T5-1000 test voltage given in Table 2. 2. Apply the voltage to the tester. Verify that the tester reads within the display limits shown.
  • Page 8: Parts And Accessories

    6. Disconnect the calibrator and the dc power supply. Reinstall the tester’s batteries. Parts and Accessories Tables 6 shows the replacement parts and accessories available from Fluke for the T5-600 and T5-1000 Electrical Testers. Table 6. Replacement Parts and Accessories...
  • Page 9: Battery Replacement

    Service Information Battery Replacement Table 6. Replacement Parts and Accessories (continued) Description Fluke Part Number T5-600/T5-1000 Electrical Tester Instruction Sheet (International) 1621978 H5 Belt Holster Accessory TP1 Probe Set, Flat Blade Accessory TP4 Probe Set, 4 mm Round Accessory Battery Replacement Figure 2 shows how to replace the batteries.

This manual is also suitable for:

T5-10007956000079559999

Table of Contents