Fluke TS 120 User Manual

Test telephone
Hide thumbs Also See for TS 120:

Advertisement

Quick Links

®
TS
120
Test Telephone
Users Guide
PN 2448072
October 2005 Rev. 2 8/10
©2005, 2008, 2010 Fluke Corporation. All rights reserved. Printed in China.
All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke TS 120

  • Page 1 ® Test Telephone Users Guide PN 2448072 October 2005 Rev. 2 8/10 ©2005, 2008, 2010 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.
  • Page 2 Networks warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke Networks does not warrant that software will be error free or operate without interruption.
  • Page 3: Table Of Contents

    Table of Contents Title Page Overview of Features ............................1 Registration ............................... 1 Contacting Fluke Networks ..........................1 Safety Information ............................2 Physical Characteristics ............................. 2 Mode Controls ............................3 Keypad ................................ 3 Dialing Keys ..............................3 Light Emitting Diodes (LEDs) ........................3 Line Cord ..............................
  • Page 4 TS120 Test Telephone Users Guide...
  • Page 5: Overview Of Features

    Overview of Features Registration The TS120 Test Telephone is a portable handset used by Registering your product with Fluke Networks gives installers, repair technicians and other authorized you access to valuable information on product updates, personnel for testing of telephone lines and for troubleshooting tips, and other support services.
  • Page 6: Safety Information

    TS120 Test Telephone Users Guide Safety Information Physical Characteristics The following IEC symbols are used either on the test See Figure 1. set or in the manual: The TS120 housing is made of high-impact plastic. The unit is designed to provide rugged service and Warning: Risk of personal injury.
  • Page 7: Mode Controls

    Physical Characteristics Mode Controls MUTE: Pressing the MUTE key shuts off the TS120 transmitter for as long as the key remains depressed. See Figure 2. POLAR: When an off-hook unit is connected to a The TALK/MONITOR switch is on the inside of the hand powered telephone line, pressing the POLAR key grip near the transmitter.
  • Page 8: Line Cord

    TS120 Test Telephone Users Guide Line Cord Dialing See Figure 4. Note If tone dialing is selected, the tones associated The TS120 comes with a line cord for connecting the with each digit will be generated as its test telephone to telephone lines. This line cord consists respective key is pressed.
  • Page 9: Polarity Check

    The line cord can be replaced by the user. To replace performed by an authorized service the line cord refer to the instructions that come with technician. the replacement line cord. To obtain a replacement line cord contact your local distributor or Fluke Networks and order part number P3218636.
  • Page 10: Specifications

    TS120 Test Telephone Users Guide Specifications Ringer Equivalent 0.14 (REN) Electrical Flash Duration 300 ms ±30 ms >14 dB (ref 600 Ω) Return Loss Physical Line Current Range 15 mA to 120 mA Measurements 10.25 in x 2.88 in x 3.38 in 275 Ω...