Introduction
This document provides the following information for the T+ and T+ PRO Electrical Testers
(hereafter referred to as the "Tester" or UUT):

• Safety information

• Symbols
• Contacting Fluke
• Specifications
• Maintenance
• Performance tests
• Parts and accessories list
• Product Warranty Statement
For complete operating instructions, refer to the T+ and T+ PRO Instruction Sheet.
Safety Information
A Warning identifies conditions and procedures that are dangerous to the user. A Caution
identifies conditions and procedures that can cause damage to the Product or the equipment under
test.
To avoid possible electric shock or personal injury, follow these
guidelines:
• Use the Tester only as specified in this document, otherwise
the protection provided by the Tester may be impaired.
• The Tester is to be used only by qualified personnel.
• Do not use the Tester if it is damaged. Inspect the case
before use. Look for cracks or missing plastic. Pay particular
attention to the insulation surrounding the connectors.
• Inspect the test leads for damaged insulation or exposed
metal. Check the test leads for continuity. Replace damaged
test leads before using the Tester.
July 2007 Rev. 1, 9/17
© 2007-2017 Fluke Corporation, All rights reserved. Printed in USA.
All product names are trademarks of their respective companies.
T+ and T+ PRO
XWWarning
Electrical Tester
1

Advertisement

Table of Contents
loading

Summary of Contents for Fluke T+

  • Page 1: Safety Information

    • Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads before using the Tester. July 2007 Rev. 1, 9/17 © 2007-2017 Fluke Corporation, All rights reserved. Printed in USA. All product names are trademarks of their respective companies.
  • Page 2 T+ and T+ PRO Calibration Information • Do not use the Tester if it operates abnormally. Protection provided by the Tester may be impaired. When in doubt, have the Tester serviced. • Do not operate the Tester around explosive gas, vapor, or dust.
  • Page 3 WEEE Directive Annex I, this product is classed as category 9 "Monitoring and Control Instrumentation" product. Do not dispose of this product as unsorted municipal waste. Contacting Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) •...
  • Page 4: Specifications

    T+ and T+ PRO Calibration Information Specifications Temperature Performance Operating ............−10 °C to 55 °C (14 °F to 131 °F) Storage ............... −30 °C to 60 °C (−22 °F to 140 °F) Relative Humidity 90 % ..............0 °C to 30 °C (32 °F to 86 °F) 75 % ..............
  • Page 5: Performance Tests

    3. Replace the battery door and secure it by turning the battery door fastener one- quarter turn clockwise. Calibration Adjustment The T+ and T+ Pro have no field calibration. If the UUT fails any performance test, contact Fluke Service for repair. See “Contacting Fluke.” Performance Tests...
  • Page 6 (T+ PRO). The beeper sounds (unless disabled) and the Tester switches to continuity mode. To complete the self test, measure a known voltage before use. If the Tester fails self test, it must not be used and requires service. See “Contacting Fluke.” Testing the LCD Display (T+ PRO)
  • Page 7 Electrical Tester Performance Tests Testing the LEDs Use the following procedure to test the LEDs: Note The Tester must remain inactive for approximately 30 seconds before performing the following test. This will force a processor reset that will display all LCD segments for approximately 1 second at power up. 1.
  • Page 8 T+ and T+ PRO Calibration Information Accuracy Tests Perform the accuracy and verification tests in Table 3. Table 3. T+ and T+ PRO Accuracy Tests Input UUT Response LCD Display (T+ PRO) Step Function Range Value (LED) Measurement Limits Pos Off 12 V +20 V 12 V LED On...
  • Page 9 Electrical Tester Performance Tests Table 3. T+ and T+ PRO Accuracy Tests (cont.) Input UUT Response LCD Display (T+ PRO) Step Function Range Value (LED) Measurement Limits 24 V 24 V 24 V LED On - - - 120 V 120 V 120 V LED On - - -...
  • Page 10 T+ and T+ PRO Calibration Information Source 5520A CALIBRATOR AutoHOLD FAST MN MX LOGGING HOLD HOLD MIN MAX MIN MAX NORMAL SCOPE CANCEL SAVE V, , ,RTD A, -SENSE, AUX V RANGE RANGE SETUP ac+dc ac+dc ac+dc ac+dc TRIG ac+dc ac+dc GUARD ac+dc...
  • Page 11 Limited Warranty and Limitation of Liability Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is two years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days.
  • Page 12 T+ and T+ PRO Calibration Information...