ESAB CIGWELD EasyWeld 130 Operating Manual page 28

Table of Contents

Advertisement

EasyWeld / HandyWeld 130
3. Over Temp Indicator
This welding power source is protected by a self resetting thermostat. The Over Temp indicator will illuminate
and the error E01 also will be displayed if the machine has over heated which normally occurs if the duty cycle
of the power source has been exceeded. Should the Over Temp indicator illuminate the output of the power
source will be disabled. Leave the power source turned On to allow the internal components to cool down.
Once the power source cools down sufficiently the Over Temp indicator will automatically switch off. Note that
the On/Off switch should remain in the On position such that the fan continues to operate thus allowing the
power source to cool sufficiently. Do not switch the power source Off if an Over Temp condition is present.
4. Control Knob
The EasyWeld/HandyWeld models are equipped with a Quick Set Feature. This allows the user to simply select
the welding process, Wire Ø (diameter), Material Plate Thickness and the pre determined welding parameters
are set and ready to weld. By further pressing the Control Knob the user can modify the Wire Feed Speed (WFS)
and Voltage (Volts Trim) settings if desired, which allows full manual settings range if required.
Press the Control Knob to select parameter to be set Wire Ø (diameter), Plate Thickness, Wire Feed Speed
(WFS) and Volts Trim.
Once the desired parameter is selected by pressing the Control Knob, the setting can be adjusted by turning the
Control Knob Clockwise to increase value or by turning the Control Knob Anti-clockwise to decrease the value.
If the Control Knob is turned slowly it will adjust the value in small increments and if turned quickly it will
adjust the value in larger increments.
Wire Feed Speed (WFS) Function
If the Welding Current is found to be too High or too Low for the application, the Wire Feed Speed can be
adjusted to the desired value.
Volts Function (Volts)
By selecting the Volts parameter either Voltage Preview range can be adjusted or the Volts Trim value (press
and hold the Control Knob for several seconds to enter Volt Trim mode) to be adjusted.
Voltage
By turning the Control Knob, you can change the Pre-set Voltage from the Factory Set Quick Set values. Once
the Volts Trim function is selected the Pre-set Voltage can be adjusted by turning the Control Knob Clockwise
to increase the value or turning the Control Knob Anti-clockwise to decrease the value.
Volts Trim
Once the Volts Trim function is selected by depressing the Control Knob for approximately 3 seconds. The
display will change from the Pre-set Value to display the Volts Trim Value.
The LED Display will show 0.0 when in the factory Quick Set Value for the selected Wire and Plate Thickness.
If the value has been changed, to return to the factory parameters simply return the Volts Trim to 0.0 to return
to the Factory Set Quick Set Voltage Value.