ReadConfig
ReportReq
ReadConfig
ReportRsp
SetFilter
timeReq
R718H2
SetFilter
timeRsp
GetFilter
timeReq
GetFilter
timeRsp
(1) Command Configuration:
MinTime = 1min、MaxTime = 1min、BatteryChange = 0.1v
Downlink: 013F003C003C0100000000
Response:
813F000000000000000000(Configuration success)
813F010000000000000000(Configuration failure)
(2) Read Configuration:
Downlink: 023F000000000000000000
Response:
823F003C003C0100000000(Current configuration)
(3) Setting the FilterTime =100ms
Downlink: 033F140000000000000000 14(Hex) = 20(Dec), 20*5ms=100ms
Response:
833F000000000000000000 (Configuration success)
833F010000000000000000 (Configuration failure)
(4) Read the FilterTime Configuration:
Downlink: 043F000000000000000000
Response: 843F140000000000000000 (Current device parameter)
(5) Setting the Pulse Counter Clear Mode = 0x01_Clear When Roll-Over
Downlink: 053F010000000000000000
Response:
853F000000000000000000 (Configuration success)
853F010000000000000000 (Configuration failure)
0x02
MinTime
0x82
(2bytes Unit: s)
0x03
0x3F
0x83
0x04
0x84
003C(H
(9Bytes,Fixed 0x00)
MaxTime
(2bytes Unit: s)
FilterTime
(1byte,Unit: 5ms)
Status
(0x00_success)
(9Bytes,Fixed 0x00)
FilterTime
(1byte,Unit: 5ms)
= 60(D
ex)
ec)
7
Reserved
BatteryChange
(1byte Unit: 0.1v)
(4Bytes, Fixed 0x00)
Reserved
(8Bytes, Fixed 0x00)
Reserved
(8Bytes, Fixed 0x00)
Reserved
Reserved
(8Bytes, Fixed 0x00)
Reserved