Technical Information
1
Technical Data
Condensate pump (M5)
Pressure hose length
Maximum head height
Maximum head height with non-return valve
Maximum drain length
Control
Table 070-1: Technical Data
4
Service
4.1
Rear Service Panel Removal
1. Remove the T30 screw securing the plastic rear service panel (Figure
070-1, Item 1).
2. Take off the rear service panel; remove the hose from the panel.
Figure 070-1: Rear Service Panel
4.2
Condensate Pump Removal
Note:
Have cloths or rags handy!
1. Disconnect the appliance from the power supply.
2. Remove the rear service panel; see Section 070-4.1.
3. Take off the metal clamp.
4. Lift the pump up and out of the condensate box.
Approximate power rating 25W
4.9' (1.5m)
4.9' (1.5m)
3.3' (1m)
13' (4m)
Time- and level-controlled
42
T 80xx