4.1

Heater Relay (1K1/1, 2K1/1) Removal

1. Disconnect the appliance from the power supply.
2. Remove the dryer lid; refer to Section 010-4.1.
3. Disconnect all electrical connections from the appropriate relay.
4. Press in on the locking tab, slide the relay back, and release it from the
appliance chassis.
4.2

RemoteVision Module Removal

1. Disconnect the appliance from the power supply.
2. Condenser models: Remove the T30 screw securing the plastic rear
service panel; take off the panel. (Refer to Figure 070-1).
3. Unclip the RemoteVision module from inside the plastic rear service panel
(condenser models), or from inside the appliance rear panel (vented
models).
4. Separate the halves of the module housing and disconnect the two Molex
plugs from the module.