Service Functions - Miele T 80 Series Technical Information

Table of Contents

Advertisement

Technical Information
2.1.4
Memory
With this function activated at program start, the program and all extra
functions selected are saved.
When the dryer is next switched on, the most recently selected program will
be preset.
Delay start is not saved.
2.1.5
Additional Cooldown Phase
Hot laundry is perceived as damp.
To reduce the perception of "damp laundry", an additional cooling phase can
be set, resulting in a lower laundry temperature at the end of the program. To
the operator, the laundry then feels less damp.
The extended cooling phase has no effect on timed drying programs.
2.1.6
Prompt to Clean Air Ducts ("Filter/Vent" Display Adjustment)
The operator can set the "Filter/Vent" LED to suit individual requirements.
For insufficient air detection, refer to Section 090-2.7.
2.1.7
Acoustical Acknowledgment for Touchpads
Set the acoustical tone to sound when a button is pressed.
2.2

Service Functions

2.2.1
Software Status
The control/power electronic (1N1, EPWL) has programmable electronic
assemblies which contain the software/programs and parameters for the
drying-process technology.
The status of the software can be seen from the ID number or program
index.
The software can be updated via the optical interface.
Note:
In models with display, the software status is indicated via the ID number.
In models without display, the software status is indicated in the program
index via the flashing rhythm of the LED.
2.2.2
Fault Memory
The control/power electronic (1N1, EPWL) monitors electrical sensors.
If the electronic registers a fault, then
the program is stopped, if necessary,
the fault is indicated via the "Drying" LED,
in case of a technical fault, a fault code is saved.
46