Miele T 80 Series Technical Information page 59

Table of Contents

Advertisement

T 80xx
4. The "Drying" LED flashes to indicate the selected option. See Table 090-5.
Note:
The component test switches off automatically 30 minutes after the last
component is activated.
Service functions
"Buzzer" LED
Software status
Fault memory; use
Start/Stop to scroll; to
delete the fault memory,
press and hold Start/Stop
until "Drying" LED goes
out
short
"Drying" LED
--
Program index XY
F 0, No fault; all OK.
F 1, Heater bank NTC short
circuit; refer to Section 090-3.7
F 2, Heater bank NTC open
circuit; refer to Section 090-3.8
F 3, Drying-air NTC short circuit;
refer to Section 090-3.9
F 4, Drying-air NTC open circuit;
refer to Section 090-3.10
F 41, Faulty electronic; refer to
1
Section 090-3.11
F 43, Wrong model; refer to
Section 090-3.12
F 50, Motor stalls and heater is
on for 3 s; refer to Section 090-
3.13
F 55, Safety time exceeded;
refer to Section 090-3.14
F 66, Air leakage fault; refer to
Section 090-3.15
59
Technical Information
Options
long
short
X
--
--
--
--
--
4
4
5
5
6
Y
--
1
2
3
4
1
3
--
5
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents