Technical Data; Table 030-1: Technical Data - Miele T 80 Series Technical Information

Table of Contents

Advertisement

Technical Information
1

Technical Data

Drum design
Maximum load
Drum volume
Drum light (H3/6)
Heater bank
Heater output
Temperature sensor
Temperature limiter

Table 030-1: Technical Data

Temperature
°F
32
41
50
59
68
77
86
95
104
113
122
131
140
149
158
167
176
185
194
199
203
212
230
248
Honeycomb design
T 80xx, T 80xx C: 13.2 lbs (6 kg)
T 8019 CI: 11 lbs (5 kg)
T 80xx, T 80xx C: 28 gal (105L)
T 8019 CI: 26 gal (100L)
E 14 bayonet closure, activation via relay on the
electronic (EPWL). USA: 120V, 15W, 572°F (300°C)
Duct heater bank (R1, R2); 2-filament
USA/CAN: 120/208-240 V, 60Hz: 2.6kW (1.44kW +
1.16kW)
MEX: 127/220V, 60Hz: 2.6kW (1.44kW + 1.16kW)
Heater bank NTC (2R30), position at heater bank (R1,
R2), drum perforation temperature
Temperature limiter (F2, SOD), position at heater bank
(R1, R2) - air entrance to drum, 347°F (175°C) ± 8
degrees
Vented dryer: ¾" (1.9 cm); condenser dryer: ½" (1.3 cm)
°C
Heater bank NTC (2R30)
0
340
5
261
10
203
15
159
20
126
25
100
30
80.2
35
64.8
40
52.7
45
43.1
50
35.5
55
29.4
60
24.5
65
20.5
70
17.3
75
14.6
80
12.5
85
10.6
90
9.13
93
8.34
95
7.86
100
6.80
110
5.14
120
3.95
22
Resistance (kΩ)
Drying-air NTC (1R30)
38.0
29.7
23.4
18.6
14.9
12.0
9.73
7.96
6.55
5.42
4.52
3.78
3.19
2.70
2.29
1.96
1.68
1.45
1.25
1.15
1.09
1.06
0.73
0.569
T 80xx