Technical Data; Function; Programming Functions; Table 090-1: Technical Data - Miele T 80 Series Technical Information

Table of Contents

Advertisement

T 80xx
1

Technical Data

Control technology
Drying technology

Table 090-1: Technical Data

1
Condenser versus vented dryer: In the condenser dryer, the electronic also has a plug
for the condensate float switch (B8/7).
2

Function

2.1

Programming Functions

2.1.1
Resetting to Factory Settings
Resets all programming options to their factory settings.
Note:
The reset takes effect immediately; it's not possible to restore the previous settings!
Operating hours are not reset.
Not possible with service-department electronics supplied as spare parts.
2.1.2
Residual Moisture Level Adjustment - Normal Wash
Normal
Extra dry
Normal +
Normal
Hand iron °
Hand iron °°
Rotary iron

Table 090-2: Residual Moisture Level Adjustment - Normal Wash

2.1.3
Residual Moisture Level Adjustment - Wrinkle-Free
Wrinkle-free
Normal +
Normal
Hand iron

Table 090-3: Residual Moisture Level Adjustment - Wrinkle-Free

Single-board
control: control/power
electronic (1N1)
Tangle prevention
Residual moisture
sensing
Insufficient-airflow
detection
Standard
Reduced moisture (drier)
-4%
-5%
-2%
-3%
0%
-1%
8%
6%
12%
10%
20%
16%
Standard
Reduced moisture (drier)
0%
-1%
2%
1%
8%
6%
45
Technical Information
Vented dryer: EPWL 315
Condenser dryer: EPWL 314
T 8019CI: EPWL 316-DI
Programs are update-capable via optical
PC interface
RemoteVision-ready
Reverse cycles are controlled by a random
generator.
Conductivity-measuring
process, residual moisture sensor (B3/1)
Via heater NTC (2R30) and fill-ring NTC (1R30)
1