Voltage Adjustment - ESAB MEK 4 Service Manual

Table of Contents

Advertisement

4a

Voltage adjustment

Applies to MEK 4 with serial number 431 . . . . . .
cmek0e10
Voltage adjustment, circuit board AP01 with article number 0486 205 880
When the MEK 4 is connected to a power unit with steplessly variable output
voltage, potentiometer RP02 on the front of the unit can be used to control the power
unit output voltage.
The +15 VB and 0 VB voltages are supplied by the power unit via connector XP01.
The voltage adjustment circuits are galvanically isolated from the other circuits at
circuit board AP01.
The remote control unit for voltage control is connected to pins F, G, H, L and M in
connector XS13. A link must be fitted between pins L and M in order to activate the
unit.
Voltage adjustment, circuit board AP01 with article number 0486 205 882
The voltage adjustment circuits are not galvanically isolated from the other circuits
on the board when circuit board - -882 is used.
- - 12 - -
cmek0de1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents