Remote Control Input - ESAB MEK 4 Service Manual

Table of Contents

Advertisement

15a
Remote control input, 12- -pole
Applies to MEK 4 with serial number 431 . . . . . .
Remote control input, MEK 4 with serial number 431 . . . . . . .
The following items can be connected to the remote control input :
Wire feed speed remote control unit: pins A, B and C in XS13.
S
Welding voltage remote control unit, if the power unit is of thyristor- - controlled
S
or transistor- -controlled type: pins F, G, H, L and M in XS13.
MEK 25 intermediate wire feeder unit.
S
15b
Remote control input, 23- - pole
Applies to MEK 4 with serial number 514 . . . . . . and above.

Remote control input

The following items can be connected to the remote control input :
Wire feed speed remote control unit: pins M, J and L in XS13.
S
Welding voltage remote control unit, if the power unit is of thyristor- - controlled
S
or transistor- -controlled type: pins J, K, L, Z and Y in XS13.
Suitable remote controls are:
S
"Aristo Control Synergic Torch" ordering number 0466 515 880.
"Aristo Control Synergic Box" ordering number 0466 801 880.
MEK 25 intermediate wire feeder unit.
S
cmek0de1
cmek0e26
- - 21 - -
cmek0e21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents