Exception - Abus TVVR35002 User Manual

Embedded nvr, local user interface
Hide thumbs Also See for TVVR35002:
Table of Contents

Advertisement

Configuration
Dwell Time
Select the dwell time for switching the
alarm output.
Activate the alarm output by ticking the "Settings"
box.
Define the schedule for the recorder alarm output in
the event of an alarm under "Settings".
Click on Copy to apply these settings to other cam-
eras.
Confirm the settings by clicking on Apply and exit the
menu by clicking on Back.
RS-232
Parameter
Baud Rate
Data Bit
Stop Bit
Parity
Setting
Set the transmission speed
you require using the baud
rate
Set the data size to be trans-
mitted
Set the stop bit value for
data transmission
Set the parity to test the er-
ror-free transmission of data
packages
Flow Ctrl
Use

Exception

Set the response of the recorder for warning messages
and system events here. To do this, activate the "Enable
Event Hint" setting.
You can trigger a warning for the following error types:
HDD Full
HDD Error
Network Disconnected
IP Conflicted
Illegal Login
Exception Error
Parameter
Audible Warning
Notify Surveillance Cen-
ter
Send Email
Trigger Alarm Output
Required to transfer data to
the Speed Dome without the
data transmission being per-
formed too quickly and data
packages being lost
Select your usage type –
"Console" (only for service
purposes) or "Transparent
Channel" (for virtual RS-485
control)
Notifications
The device emits a repeated
signal tone.
A notification is sent to the
CMS software event log.
An email is sent to a speci-
fied email address.
The selected alarm output is
switched in the event of a
fault.
32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tvvr35011Tvvr45021Tvvr45030Tvvr60011Tvvr60021

Table of Contents