7-SEGMENT DISPLAY
SCREEN 3 (SETTING MODE 1)
Setting
No.
1
Cool Airflow Trim Hi
2
Cool Airflow Trim Int
3
Cool Airflow Trim Low
4
Cool Profile
5
Cool ON Delay
6
Cool OFF Delay
7
Dehumidfication Select
SCREEN 4 (SETTING MODE 2)
Setting
No.
2
Set Maximum Current
3
Vertical Rise
4
System Verification Test
8
Pump Down
9
Charge Mode
Maximum Compressor RPS
10
for Cooling
* See service manual for detailed information.
NOTE : Parameters as per factory setting are highlighted in bold and underlined.
Contents
0: -15%
1: -12%
2: -9%
3: -6%
4: -3%
5: 0%
0: -15%
1: -12%
2: -9%
3: -6%
4: -3%
5: 0%
0: -15%
1: -12%
2: -9%
3: -6%
4: -3%
5: 0%
0: A
1: B
0: 5 sec.
1: 10 sec.
0: 30 sec.
1: 60 sec.
0:ON
Contents
0: Same Level
1: Outdoor Lower
2: Indoor Lower
0: ON
0: ON
0: ON
Setting
6: 3%
7: 6%
8: 9%
9: 12%
10: 15%
6: 3%
7: 6%
8: 9%
9: 12%
10: 15%
6: 3%
7: 6%
8: 9%
9: 12%
10: 15%
2: C
3: D
2: 20 sec.
3: 30 sec.
2: 90 sec.
3: 120 sec.
1:OFF
Setting
N/A
1: OFF
1: OFF
1: OFF
*
Notes
Notes
Future Use