Room Air Conditioners Owner's Manual Manuel du proprietaire Manual del propietario Room Air Conditioner Climatiseur domestique Aire acondicionado para habitaci6n Keep manual for future reference. Be sure manual stays with air conditioner. Conserver ce manuel pour r6f6rence ult6rieure. S'assurer le manuel accompagne toujours le climatiseur.
Thank You for buying a dependable, energy saving and easy to operate Arnanaroom air conditioner. This manuaJ contains useful information you to maintain, operate, install and safely use your room air conditioner. Your air conditioner cleans, cools and dehumidifies the air in your room to provide yau with the ultimate bvel of comfort.
WARNING: Following these basic precautions will reduce the risk of fire, electrical shock, injury or death when using your air conditioner. 1) Air conditioner must be connected to proper electrical outlet with the correct ebctricaJ supply. (see table) 2) Proper grounding must be ensured to reduce the risk of shock and fire. DO NOT CUT OR REMOVE THE GROUNDING PRONG.
PAGE A Word From A.nana Product Registration Safety Precautions Warnings Electrica| Safety Tips Energy Saving Guide Features Operating Guide 8-12 Normal Operating Sounds Operating instructions 8-12 |nstollations 13-20 Parts Tools Installing Unit into A Window 15-20 Clean and Care Guide 21-22 Troub|eshoating 22-23...
Following the safety messages is very important. These messages can save you from being injured or kilbd. Warning symbols alert you to be careful and means Danger. Always follow instructions to be safe and reduce chances of injury or death. Warning and Danger signs will precede safety messages.
o Air Conditioners are designed for use in a double hung window or through the wall installation only. (As applicable in your model) • While installing unit be sure to tilt air conditioner 5 degree outward to have the water drip outside the house. •...
vent controller side vent louvers -_. electronic touch pad easy-access filters ACE185R,ACE245R,ACE156E,ACE185E,ACE245E,ACEX186E ]. Thermostat comfortable dry stage. You can usethis feature This allows you to adjust the temperature of the air. alone in case you do not desire to use the air conditioner, The lower the setting the cooler the air temperature.
Page 8
7. Vent 12. UV Light The Fresh Air Vent allows the air conditioner Filters Impurities for Cleaner recirculate inside air, draw fresh air into the room Unique Photocatdylic Air Purifier with UV Light and exhaust stale air to the outside. Active Tio2 Converts Oxygen&wafer into Hydroxyl...
Normal Operating Saunds The following soundsare normally heard during the operation of an air conditioner. * Cool airflow movementas dictated by the set fan speed. ° Water sounds.This is normal as your air conditioner actsas a dehumidifier also. Thusyou will hear water soundsfrom water drops falling on the condenser.
Page 10
After you plug in the unit it will perform a selftest. AJJthe dispJay lights will turn on for 3 seconds. The LEDdisplay wiJJread "88". If any display light fails to turn on you may need serviceon the unit. After the 3 seconds self test the unit wiJJautomatically go to the stand by mode.
Page 11
Fig. Control Panel Once the function mode is decided you will have to set the fan speed.(See fig. #4) Every time you press the SPEED button, fan speed will change between LOW, HIGH,MED. 1) If you choose the COOL mode you can run the fan in one of the 3 speeds HIGH, MED, LOW.
Page 12
Fig. # 4 Control Panel. iiiiiii iiiiiii ¸ Timer on or Timer off mode is used to pre-start or shut off your unit in advance. You can program this up to 24 hours in advance. You can use the Timer in 4 functions i.e. COOL, Energy saver, Dehumid or Fan .
Page 13
Fig. # 5 Control Panel. Adjusting the Air Flow Direction Airflow can be adjusted by changing the direction of the air conditioner's louvers. This can also increase the cooling efficiency of the air conditioner. Adjusting Vertical Flow Direction Adiusting Horizontal Air Flow Direction Adjusting...
Before you install your air conditioner check the following: The unit is free of all obstructionsinside and outside the room e.g. drapes, curtains, furniture, plants, shrubs,bushes,trees, other structureslike building, garage etc. Air conditioner musthave clear unobstructedairflow through the condenserto removethe heat. 2) Thewindow is strongenough to hold the weight of the air conditioner.
Parts Pa4s Supplied window seal gasket wood screws 31/32' 19/32 _long screw ad basepan angle Iocknut Iocknul curtain a_achment insqallafion bracket Remote _i-_ left and right screws 13/32 ' (left and right) control "CR2025" baHery side curtains Model: ACE 185R,ACE245R,ACE 156E,ACE185E,ACE245E,ACEX 186E You will need to have the following tools to help you in the installation of...
installing Unit into A Window Window Opening Requirements The air conditioner is designed to fit into double or single hung sash type windows. Each of the units comes with an installation kit that provides adjustable mounting louvers, to fill the gaps between the sides of the unit, and the window frame.
Page 17
ASSEMBLE CURTAINS/TOP RAIL Install lop rail with four 13/32" screws. Slide left-hand curtain assembly into left end of top and bottom rails. Repeat for right-hand curiain assembly, Fasten curtain retainer strips to sides of outer case wit_ six 13/32' screws. Storm window installation Mobile...
Page 18
iNSTALL OUTER CASE IN WINDOW Place outer case in window. Lowe_ sash until it rests behind _ront flange of top rail. Boffom rail must rest behind window sill rail Expand window Jrame. install four wood screws 31/32" Two in each upper right and left of he curtains.
Page 19
iNSTALL SASH B_CKET & SEAL GASKET Install sash bracket on top of indoor window sash with one wood screw 3 ]/32" to prevent raising of window from the outside. Screw anchor d recfly into side of window frame. For hard wood or metal window frames, drill a pilot hole to start screw, Imporlant:Be careful not to drill pilot hole too deep...
Page 20
WoB |nstoNotions: slide-out chassis only Note: Remove the 2 shipping screws on the top of the air conditioner that hdd the chassis to the outer shd[ casing. Once removed, these do not have to be re-instdbd. To ensure that your air conditioner is properly installed in the wall, it is recommended that it be installed by a certified technician who is familiar with through the wall installations.
Page 21
Fig. # 20 _/pical casing outward level casing 4) The casing should be tilted 1/4" outside so as to drain the excess dehumidified water. 5) Properly insulate any opening bebveen the casing and the frame. 6) Using the screw holes on the sides of the unit, which are for the window mounting kit and the screw hobs in the top mounting kit rail, attach the casing to the wood frame.
• Always unplug your air conditioner before c|eanlng. • The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner. How to remove the air filter 1.
To store your air conditioner, after the season, remove the unit from the window as per the installation guide. Repack the unit in its original box and store away. If your unit is installed in a wall or you do not intend to remove it from the window then cover the outside with a winter cover.
Air conditioner working but room not coo|ing: * Room may have appliances that produce heat. Use an exhaust fan to remove excess heat. " Redirect the airflow. Remove any obstacles. o All doors and windows need to be closed so cool air does not escape the room.