Amana AVXC20 Series Service Instructions Manual page 54

Inverter condensing unit
Table of Contents

Advertisement

SERVICING
DIAGNOSTIC CODES
7 SEGMENT LED
(characters will alternate)
(no display)
GREEN CFM LED
54
INTERNAL CONTROL FAULT / NO POWER
On
STANDBY, WAITING FOR INPUTS
Ec
HEATER KIT TOO LARGE, TOO SMALL, OR NO MATCH
E5
FUSE OPEN
EF
AUXILIARY SWITCH OPEN
d0
DATA NOT ON NETWORK
d1
INVALID DATA ON NETWORK
d4
INVALID MEMORY CARD DATA
b0
BLOWER MOTOR NOT RUNNING
b1
BLOWER MOTOR COMMUNICATION ERROR
b2
BLOWER MOTOR HP MIS-MATCH
b3
BLOWER MOTOR OPERATING IN POWER, TEMP., OR SPEED LIMIT
b4
BLOWER MOTOR CURRENT TRP OR LOST ROTOR
b5
BLOWER MOTOR ROTOR LOCKED
b6
OVER / UNDER VOLTAGE TRIP OR OVER TEMPERATURE TRIP
b7
INCOMPLETE PARAMETER SENT TO MOTOR
b9
LOW INDOOR AIRFLOW
h1
EMERGENCY HEAT LOW - COMMUNICATING MODE ONLY
h2
EMERGENCY HEAT HIGH - COMMUNICATING MODE ONLY
FC
FAN COOL - COMMUNICATING MODE ONLY
FH
FAN HIGH - COMMUNICATING MODE ONLY
F
FAN ONLY
H1
ELECTRIC HEAT LOW
H2
ELECTRIC HEAT HIGH
EACH FLASH REPRESENTS 100 CFM
(USE FOR AIRFLOW APPROXIMATION ONLY)
EXAMPLE: 8 FLASHES = 800 CFM
DESCRIPTION OF CONDITION
0140A00070-A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avxc200241Avxc200361Avxc200481Avxc200601