Connection Of An Exit Button; Connection Of An External Camera; Connection For An Apartment Door Button - golmar G2+ Soul kit User Manual

2-wire installation art 7h monitor
Hide thumbs Also See for G2+ Soul kit:
Table of Contents

Advertisement

SOUL S5110/ART 7
WIRING DIAGRAMS

Connection of an exit button

The exit button allows remote activation of the lock release connected between the CV- and CV+ terminals (by
default) or the relay output (see p. 3
possibility of setting it to between 0.5 and 10 seconds (see pp. 3 -3 ).

Connection of an external camera

It is possible to connect a Golmar AHD4-3601x analogue CCTV camera to each of the door panels, which can be
viewed (see pp. 3 -3 ) from the monitor. The camera needs to have a local PSU-121 power supply

Connection for an apartment door button

Only connect the apartment door button to the master monitor of the apartment that will be receiving the call. The
signal received is then transmitted to the slave monitors in the same apartment.
H
VIDEO DOOR ENTRY SYSTEM KIT
3 5
-3
3 5
SOUL PANEL/1
Mains
110~240Vac
BUS
BUS
CV-
CV+
AP+
C
NA
GND
CCTV
AP-
). The delay time in carrying out the activation is 3 seconds
3 5
SOUL PANEL/1
BUS
BUS
CV-
CV+
AP+
C
NA
GND
CCTV
AP-
POWER SUPPLY
PSU-121 (Code 31690144)
Important: Set the camera with an analogue
CVBS signal, as described in the accompanying
AHD4-3601x camera manual.
ART 7 /G2+
H
HZ
HZ
ANALOGUE CCTV CAMERA
AHD4-3601x (Code 31600144)
JOYSTICK
32
, with the

Advertisement

Table of Contents
loading