Husqvarna K1270 II Workshop Manual page 29

Hide thumbs Also See for K1270 II:
Table of Contents

Advertisement

6.2.7 To examine the short circuit cable and the
stop switch
1. Remove the starter and the short circuit cable on the
ignition unit.
2. Put back the starter and make sure that the spark
plug makes a spark.
3. Examine the short circuit cable.
a) Use a battery in series with a test lamp or a
multimeter.
b) Connect to the short circuit cable and the engine
body.
The lamp must not come on when the stop switch is in
operation mode.
If the lamp comes on, examine the insulation on the
short circuit cable.
If the short circuit cable is not damaged, examine the
stop switch. If the short circuit cable and the stop switch
operate correctly, replace the ignition unit.
1273 - 001 - 04.11.2019
6.2.8 To remove the stop switch
1. Remove the screw and the cable.
2. Pull out the the switch approximately 10 mm (A).
C
A
3. Push the notch with a screwdriver (B).
4. Remove the switch (C).
6.2.9 To assemble the stop switch
1. Push the switch into position (A).
B
2. Push the side until it locks (B).
3. Push the side until it locks (C).
B
C
A
Repair and servicing - 29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents