Battery:stop:voltage <Nrf; Battery:stop:current <Nrf - ITech IT-M3100 Programming Manual

Programmable dc power supply
Table of Contents

Advertisement

Returns
NR3
BATTery:STOP:VOLTage <NRf+>
This command sets the cut off voltage.
Syntax
BATTery:STOP:VOLTage <NRf+>
Arguments
<MINimum-MAXimum|MINimum|MAXimum>
Default value
Not applicable
Example
BATT:STOP:VOLT 4.0
Query command
BATTery:STOP:VOLTage? [MINimum|MAXimum]
Returns
NR3
BATTery:STOP:CURRent <NRf+>
This command sets the cut off current.
Syntax
BATTery:STOP:CURRent <NRf+>
Arguments
<MINimum-MAXimum|MINimum|MAXimum>
Default value
Not applicable
Example
BATT:STOP:CURR 3.0
Query command
BATTery:STOP:CURRent? [MINimum|MAXimum]
Copyright © Itech Electronic Co., Ltd.
Battery Commands
65

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IT-M3100 and is the answer not in the manual?

Questions and answers

Table of Contents