[Source:]Voltage:under:protection:delay <Nrf; [Source:]Voltage:under:protection:state <Bool - ITech IT-M3100 Programming Manual

Programmable dc power supply
Table of Contents

Advertisement

[SOURce:]VOLTage:UNDer:PROTection:DELay
<NRf+>
This command sets the under-voltage delay time of the power supply.
Syntax
[SOURce:]VOLTage:UNDer:PROTection:DELay <NRf+>
Arguments
<0.00-10.00>
Default value
10.00S
Example
VOLT:UND:PROT:DEL 10.00
Query command
[SOURce:]VOLTage:UNDer:PROTection:DELay? [MINimum|MAXimum]
Returns
NR3
[SOURce:]VOLTage:UNDer:PROTection:STATe <bool>
This command enables or disables the under-voltage function.
Syntax
[SOURce:]VOLTage:UNDer:PROTection:STATe <bool>
Arguments
0|OFF|1|ON
Default value
0
Example
VOLT:UND:PROT:STAT ON
Query command
[SOURce:]VOLTage:UNDer:PROTection:STATe?
Returns
0|1