Default value
MIN
Example
CURR:UND:PROT 0.500
Query command
[SOURce:]CURRent:UNDer:PROTection[:LEVel]? [MINimum|MAXimum]
Returns
<NR3>
[SOURce:]CURRent:UNDer:PROTection:DELay
<NRf+>
This command sets the under-current delay time of the power supply.
Syntax
[SOURce:]CURRent:UNDer:PROTection:DELay <NRf+>
Arguments
<0.00-10.00>
Default value
10.00S
Example
CURR:UND:PROT:DEL 10.000
Query command
[SOURce:]CURRent:UNDer:PROTection:DELay? [MINimum|MAXimum]
Returns
<NR3>
[SOURce:]CURRent:UNDer:PROTection:STATe <bool>
This command enables or disables the under-current function.
Syntax
[SOURce:]CURRent:UNDer:PROTection:STATe <bool>
Arguments
<0|OFF|1|ON>