7.3.2. VictronConnect history screen

The history screen shows a summary of the data collected over the previous 30 days. Swipe the screen to the right or left to show
any of the 30 days.
To switch between portrait or landscape screen presentation click the fragmented square icon,
screen.
The daily log shows:
• Solar yield: The energy (Wh) converted for that day.
• Solar Pmax: The maximum power (W) recorded during the day.
• Solar Vmax: The highest voltage (V) from the PV array during the day.
• Battery max and min: The first figure shows the maximum battery voltage (Vmax) for the day. The figure below is the minimum
battery voltage(Vmin) for the day.
• Errors: This shows the daily number of errors, if any. To get more information about the error(s), click the orange dot. You may
need to slide the display on your device up to see the errors.)
• Lifetime total: This shows the total energy converted by the installation (W and is not re-settable).
• Since reset: This shows how much energy has been converted by the installation since the last reset.
Clicking on any bar (day) in the graph will expand the information. It will show the time and percentage of the total charge time
that the solar charger has spend in each Bulk, Absorption and Float charge stage.
You can use the charge times to see if the PV array is properly sized for your requirements. A system which
never reaches the float stage may need more panels. Or perhaps the load should be reduced?
The history can be exported as a comma separated file (CSV) by clicking the three connected dots symbol
at the top right of the history screen. The symbol varies, depending on what platform VictronConnect is used.
The history can be reset by clicking the clock with arrow symbol

7.3.3. VictronConnect error reporting

VictronConnect will indicate active errors while VictronConnect is actively connected to the solar charger. The error will show up in
a pop-up window in the status screen together with the error number, name and a short error description.
VictronConnect also displays historical errors. To see these errors, navigate to the "History" tab and look at the bottom of each
day column. If there is an error, an orange dot will indicate an error.
Page 34
MPPT solar charger manual
at the top right of the history screen.
or
, at the top left of the
or the save symbol