Victron energy BlueSolar MPPT 75/10 Manual

Victron energy BlueSolar MPPT 75/10 Manual

Charge controllers
Hide thumbs Also See for BlueSolar MPPT 75/10:

Advertisement

BlueSolar charge controllers
MPPT 75/10
MPPT 75/15
MPPT 100/15
Manual
Handleiding
Manuel
Anleitung
Manual
Användarhandbok

Advertisement

Table of Contents
loading

Summary of Contents for Victron energy BlueSolar MPPT 75/10

  • Page 1 Manual Handleiding Manuel Anleitung Manual Användarhandbok BlueSolar charge controllers MPPT 75/10 MPPT 75/15 MPPT 100/15...
  • Page 2: General Description

    1 General Description 1.1 Ultra fast MPPT tracking Especially in case of a clouded sky, when light intensity is changing continuously, a fast MPPT algorithm will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers. 1.2 VE.Direct For a wired data connection to a Color Control panel, PC or other devices 1.3 Load output...
  • Page 3 1.7 Three step charging The controller is configured for a three step charging process: Bulk – Absorption - Float. See section 3.8 and section 5 for default settings. See section 1.8 for user defined sttings 1.7.1. Bulk During this stage the controller delivers as much charge current as possible to rapidly recharge the batteries.
  • Page 4: Important Safety Instructions

    2. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS - This manual contains important instructions that shall be followed during installation and maintenance. Danger of explosion from sparking Danger of electric shock ● It is advised to read this manual carefully before the product is installed and put into use.
  • Page 5: Installation

    3. Installation WARNING: DC (PV) INPUT NOT ISOLATED FROM BATTERY CIRCUIT CAUTION: FOR PROPER TEMPERATURE COMPENSATION THE AMBIENT CONDITION FOR CHARGER AND BATTERY MUST BE WITHIN 5°C. 3.1. General ● Mount vertically on a non-flammable substrate, with the power terminals facing downwards.
  • Page 6 ● Maximum open circuit PV voltage: 75V respectively 100V For example: 12V battery and mono- or polycristalline panels connected to a 75V controller ● Minimum number of cells in series: 36 (12V panel). ● Recommended number of cells for highest controller efficiency: 72 (2x 12V panel in series or 1x 24V panel).
  • Page 7 Some loads with high inrush current can best be connected directly to the battery. If equipped with a remote on-off input, these loads can be controlled by connecting the load output of the controller to this remote on-off input. A special interface cable may be needed. Alternatively, a BatteryProtect may be used to control the load.
  • Page 8 3.8 Battery charging information The charge controller starts a new charge cycle every morning, when the sun starts shining. Default setting: The maximum duration of the absorption period is determined by the battery voltage measured just before the solar charger starts up in the morning: Battery voltage Vb (@start-up) Maximum absorption time Vb <...
  • Page 9: Troubleshooting

    4. Troubleshooting Problem Possible cause Solution Charger does Reversed PV connection Connect PV correctly not function No fuse inserted Insert 20A fuse Reversed battery Blown fuse Connect battery correctly connection Replace fuse A bad battery connection Check battery connection Use cables with larger cross Cable losses too high section Large ambient temperature...
  • Page 10: Specifications

    5 Specifications BlueSolar charge controller MPPT 75/10 MPPT 75/15 MPPT 100/15 Battery voltage 12/24V Auto Select Maximum battery current Nominal PV power, 12V 1a,b) 145W 220W 220W Nominal PV power, 24V 1a,b) 290W 440W 440W Max. PV short circuit current 2) Automatic load disconnect Yes, maximum load 15A Maximum PV open circuit voltage...
  • Page 11 Figure 1a: configuration pins of the VE.Direct communication port, 75V models Figure 1b: pin numbering of the VE.Direct communication port. 4 3 2 1...
  • Page 12 Figure 2a: configuration pins of the VE.Direct communication port, 100V model Figure 2b: pin numbering of the VE.Direct communication port, 100V model...
  • Page 13 Figure 3: Battery management options EN: No bridge: BatteryLife algorithm NL: Geen brug: BatteryLife algoritme FR: Pas de pont : Algorithme BatteryLife DE: Keine Überbrückung: BatteryLife Algorithmus ES: Ningún puente: algoritmo BatteryLife SE: Ingen brygga: BatteryLife-algoritm EN: Bridge between pin 1 and 2: 75V models Low voltage disconnect: 11.1V or 22.2V Automatic load reconnect: 13.1V or 26.2V...
  • Page 14 Figure 4: Power connections Figure 5: The Victron inverters model Phoenix 12/800, 24/800, 12/1200 and 24/1200 can be controlled by connecting the right side connection (1) of the inverter remote control directly to the solar charger load output. Similarly, all Phoenix VE.Direct inverters can be controlled by connecting to the left side connection of the...
  • Page 15 Serial number: Version : 05 Date : July 24 , 2018 Victron Energy B.V. De Paal 35 | 1351 JG Almere PO Box 50016 | 1305 AA Almere | The Netherlands General phone : +31 (0)36 535 97 00 E-mail : sales@victronenergy.com...