During this stage the solar charger switches to the constant voltage mode, where a pre-set absorption voltage is applied. When
the charge current decreases below 1A or if the pre-set absorption time has elapsed, the battery is fully charged and the solar
charger will enter the Float stage. Note that when an automatic equalisation is being performed this will also be reported as
absorption.
Float
During this stage the float voltage is applied to the battery to maintain a fully-charged state. When the battery voltage drops
below float voltage during at least 1 minute, a new charge cycle will be triggered.
External control
This will be displayed when another device is controlling the charge behaviour of the solar charger, bypassing its normal charge
algorithm. Examples are when the solar charger is controlled by an ESS system or a managed battery.
• In case the charger is not charging a "Why is the charger off?" message will display. When clicking on this message, a new
window will open with more information as to why the solar charger is not charging.
Load output
• The state of the load output, being switched on or switched off.
• The current drawn by the loads like electronic devices, lights, fridge and so on.
• The power drawn by the loads.
Note that for the load output readings to be reliable, all loads must be wired directly to the load output,
including their negative terminals. If this is not the case consider adding a
measure all current going to or being drawn from the battery, including loads connected directly to the
battery and not just the load output terminals of the solar charger.

7.3.2. VictronConnect history screen

The history screen shows a summary of the data collected over the previous 30 days. Swipe the screen to the right or left to show
any of the 30 days.
To switch between portrait or landscape screen presentation click the fragmented square icon,
screen.
The daily log shows:
• Solar yield: The energy (Wh) converted for that day.
• Solar Pmax: The maximum power (W) recorded during the day.
• Solar Vmax: The highest voltage (V) from the PV array during the day.
• Battery max and min: The first figure shows the maximum battery voltage (Vmax) for the day. The figure below is the minimum
battery voltage(Vmin) for the day.
• Errors: This shows the daily number of errors, if any. To get more information about the error(s), click the orange dot. You may
need to slide the display on your device up to see the errors.)
• Lifetime total: This shows the total energy converted by the installation (W and is not re-settable).
• Since reset: This shows how much energy has been converted by the installation since the last reset.