Pv Voltage Too High - Victron energy BlueSolar MPPT 75/10 Manual

Solar charger
Hide thumbs Also See for BlueSolar MPPT 75/10:
Table of Contents

Advertisement

Possible causes can be:
• Loose or missing battery cables.
• Loose cable connections, or badly crimped cable terminals.
• A blown (or missing) fuse in the battery supply cable.
• Open (or faulty) circuit breaker in the battery supply cable.
• Missing or incorrectly wired battery cables.
Battery voltage check
1.
Use the VictronConnect App, a connected display or a GX device to find out what the battery terminal voltage of the
controller is. If this is unavailable use a multi meter to measure the battery voltage at the terminals of the controller.
2.
Use a multi meter to measure the voltage at the battery terminals.
3.
Compare the two voltages.
4.
If the battery voltage and the controller voltage are not the same, then investigate why this is. Follow the path from the
controller to the battery to investigate what could be the cause.
Battery supply check
1.
Check and verify that all cabling is connected correctly, and that no wiring mistakes have been made.
2.
Check if all cable connections are tight while taking maximum torque levels into consideration.
3.
Check if all cable lugs or cable terminals have been crimped correctly.
4.
Check fuses and/or circuit breakers.
If a blown fuse is found, first ensure that the battery polarity has been correctly wired before replacing the
fuse. See next paragraph for more information on reverse battery polarity.

9.2.9. PV voltage too high

The PV voltage should never exceed the maximum rated PV voltage of the solar charger. The maximum PV voltage rating is
printed on the front or on the side of the housing of the controller.
The solar charger stops charging if the PV voltage exceeds the maximum rated PV voltage. At the same time, it will display an
overvoltage error #33, and will fast blink its absorption and float LED.
Charging will not recommence until the PV voltage has dropped 5V below the rated maximum voltage.
When investigating a high voltage issue, also look at the history of the VictronConnect App, solar charger display or GX device.
Check the highest PV voltage for each day (Vmax) and also look for past overvoltage warnings.
Page 42
MPPT solar charger manual
V
OR
V
Troubleshooting and Support

Hide quick links:

Advertisement

Table of Contents
loading