6.3

Recommended nozzles

The burner complies with the emission requirements of the EN
267 standard.
In order to guarantee that emissions do not vary, recommended
and/or alternative nozzles specified by manufacturer in the In-
struction and warning booklet should be used.
It is advisable to replace nozzles every year dur-
ing regular maintenance operations.
WARNING
Burner RG1F
Steinen
type S - Q - H;
Danfoss
type S - B - H;
Delavan
type B - W;
Monarch type R - NS.
For low temperature ignitions (less than + 8 °C) proceed as
follows:
 use hollow-cone or semi-hollow nozzles:
Delavan type W; Danfoss type H;
Monarch type NS; Steinen type H,
or (alternatively) increase the pump pressure up to 14 bar.
 If necessary, use both solutions.
Burners RG2 - RG2F
Steinen
type S - Q;
Danfoss
type S - B;
Delavan
type B - W;
Monarch type R.
For nozzles of 1.75 - 2.00 - 2.25 GPH, it is advisable to use full
cones.
Burner RG3
Steinen
type S - Q;
Danfoss
type S - B;
Delavan
type B - W;
Monarch type R.
For 3.00 - 3.50 GPH nozzles, preferably use full cones.
The use of nozzles other than those specified by
manufacturer and inadequate regular mainte-
nance may result into emission limits non-con-
forming to the values set forth by the regulations
in force, and in extremely serious cases, into po-
tential hazards to people and objects.
CAUTION
The manufacturing company shall not be liable for
any such damage arising from non-observance of
the requirements contained in this manual.
Start-up, calibration and operation of the burner
25
GB