Deluge valve, automatic resetting 2-1/2 inch (dn65), 250 psi (17,2 bar)

Advertisement

Quick Links

Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
Model DV-3HP Deluge Valve, Automatic Resetting
2-1/2 Inch (DN65), 250 psi (17,2 bar)
Thread x Thread or Groove x Groove
Table of
Contents
Technical Data . . . . . 3
Valve Trim . . . . . . . . 3
Installation . . . . . . . . 17
Procedures . . . . . . . 17
Limited Warranty . . . . 20
Page 1 of 20
General
Description
The 2-1/2 inch (DN65), Model DV-3HP
Automatic Resetting Deluge Valve is a
quick opening, hydraulically operated
differential type valve designed for fire
protection system service. It is used as
an "automatic water control valve" in
deluge, preaction, and special types of
fire protection systems such as foam-
water and double interlock. The DV-
3HP Valve also provides for actuation
of fire alarms upon system operation.
. . . 12
The automatic resetting feature of the
DV-3HP provides for easy, external
resetting, without having to open a
valve handhole cover to manually re-
position a clapper and latch mecha-
nism.
Operation of a DV-3HP Valve is pro-
vided by an actuation (detection) sys-
tem that is separate from the normally
dry system piping. Trim configuration
options for automatic operation of the
DV-3HP include wet pilot actuation,
dry pilot actuation, and electric actua-
tion. Trim arrangements also provide
for local emergency (manual) release
of the DV-3HP Valves.
The compact and easily installed trim
arrangements have been designed so
that the DV-3HP Valve may be in-
stalled "flow left" or "flow right"
The Model DV-3HP Deluge Valve is a
redesignation for the Gem Model
F446.
JANUARY, 2004
WARNING
The Model DV-3HP Deluge Valve de-
scribed herein must be installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the integrity of these devices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or manufac-
turer should be contacted relative to
any questions.
TFP1355

Advertisement

Table of Contents
loading

Summary of Contents for Tyco DV-3HP

  • Page 1: Table Of Contents

    Valve Setting nism. Procedures ..17 WARNING Operation of a DV-3HP Valve is pro- The Model DV-3HP Deluge Valve de- vided by an actuation (detection) sys- Care and Maintenance . 18 scribed herein must be installed and...
  • Page 2 ..CH: Common Hardware 10 Facing Retainer . . . See (c) Retainer Screw ..See (c) Thread x Groove Adapter (Optional) FIGURE 1 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVE — ASSEMBLY —...
  • Page 3: Technical Data

    Ring and Center Valve are are bronze, and the Seat Ring is brass. The Facing GRAPH A retainer is brass. The Cap Screws and 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVE Facing Retainer Screw are stainless — NOMINAL PRESSURE LOSS VERSUS FLOW — steel.
  • Page 4: Wet Pilot Actuation

    TD1382. used for wet pilot lines. The maximum height of a wet pilot line above the DV-3HP Valve must not ex- ceed the limitations given in Graph B as a function of the minimum water supply pressure to the DV-3HP Valve and the length of the pilot line to the most remote pilot sprinkler.
  • Page 5 10 (3,05) (1,4) (2,6) (4,1) (5,5) (6,9) (8,3) (9,7) (11,0) (12,1) NOTE: IF SUPPLY PRESSURE IS VARIABLE, SUPPLY PRESSURE, ASSUME MINIMUM EXPECTED VALUE. PSI (BAR) GRAPH B 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVE — WET PILOT DESIGN CRITERIA —...
  • Page 6 (Standard Order). Route all Tubing to Drip Funnel. FIGURE 3 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVES — EXPLODED VIEW OF WET PILOT ACTUATION TRIM (52-445-2-101) — (Refer to Figure 12 to see the factory assembled trim segments, as well as functional callouts of the trim components)
  • Page 7 (400,1 mm) MINIMUM CLEARANCE, ADDITIONAL 2" (500 mm) RECOMMENDED. 6-1/4" 5-5/8" 1-5/8" (158,8 mm) (142,9 mm) (41,3 mm) LEFT VIEW FRONT VIEW FIGURE 4 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVE — WET PILOT ACTUATION / NOMINAL INSTALLATION DIMENSIONS —...
  • Page 8: Dry Pilot Actuation

    Diaphragm Chamber of the The Dry Pilot Actuation Trim provides NOTES DV-3HP Valve, and the force differen- for installation of a detection system tial holding the Center Valve Assembly The dew point of the pilot line air pres-...
  • Page 9 Graph C. GRAPH C 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVE — DRY PILOT LINE PRESSURE REQUIREMENTS — The Pressure Relief Valve (Ref. Item D6 - Fig. 6) is factory set to relieve at a pressure of approximately 45 psi (3,1 bar);...
  • Page 10 (Standard Order). Route all Tubing to Drip Funnel. FIGURE 6 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVES — EXPLODED VIEW OF DRY PILOT ACTUATION TRIM (52-445-2-102)— (Refer to Figure 12 to see the factory assembled trim segments, as well as functional callouts of the trim components)
  • Page 11 (400,1 mm) MINIMUM CLEARANCE, ADDITIONAL 2" (500 mm) RECOMMENDED. 6-1/4" 5-5/8" 1-5/8" (158,8 mm) (142,9 mm) (41,3 mm) LEFT VIEW FRONT VIEW FIGURE 7 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVE — DRY PILOT ACTUATION / NOMINAL INSTALLATION DIMENSIONS —...
  • Page 12: Electric Actuation

    DV-3HP Valve, the Sole- hazardous locations. noid Valve must remain energized in order for the DV-3HP Valve to remain The Electric Actuation Trim is only to open. be used in conjunction with an electric...
  • Page 13 (Standard Order). Route all Tubing to Drip Funnel. FIGURE 9 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVES — EXPLODED VIEW OF ELECTRIC ACTUATION TRIM (52-445-2-103) — (Refer to Figure 12 to see the factory assembled trim segments, as well as functional callouts of the trim components)
  • Page 14 15-3/4" (400,1 mm) MINIMUM CLEARANCE, ADDITIONAL 2" (500 mm) RECOMMENDED. 6-1/4" 5-5/8" 1-5/8" (158,8 mm) (142,9 mm) (41,3 mm) LEFT VIEW FRONT VIEW FIGURE 10 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVE — ELECTRIC ACTUATION / NOMINAL INSTALLATION DIMENSIONS —...
  • Page 15: Operating Principles

    The nomi- in order for the DV-3HP to remain nal trip ratio is 2.5 to 1, i.e., the DV-3HP open. Valve operates (opens) when the pres- sure in the Diaphragm Chamber is re- duced to approximately 40 percent of the water supply pressure.
  • Page 16 Port Identification. FUNNEL Route all Tubing to Drip Funnel. 1-1/4 INCH NPT CONNECTION TO DRAIN FIGURE 12 2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVE —FACTORY PREASSEMBLED TRIM SEGMENTS— —FUNCTIONAL CALLOUTS FOR TRIM COMPONENTS— — ASSEMBLY PROCEDURE FOR VALVE TRIM —...
  • Page 17: Installation

    Graph C. Drain Valve open. • Fire alarm setting at approximately Heat tracing of the DV-3HP Valve or its Step 4. Depress the plunger of the associated trim is not permitted. Heat 15 psi (1,0 bar) below the minimum...
  • Page 18: Care And Maintenance

    If there are no 3, 4, and 5, if water must be prevented nection to or from the diaphragm leaks, the DV-3HP Valve is ready to be from flowing beyond the riser. chamber or, a leak in the diaphragm placed in service and the Main Control •...
  • Page 19 Dry Pilot Line Pressure the leakage problem. If there are no Gauge. leaks, the DV-3HP Valve is ready to be • Remove the 1/4 inch Plug from the placed in service and the Main Control Gauge Test Valve.
  • Page 20: Limited Warranty

    EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446...

Table of Contents