Tyco DV-3HP Manual page 10

Deluge valve, automatic resetting 2-1/2 inch (dn65), 250 psi (17,2 bar)
Table of Contents

Advertisement

Page 10 of 20
NO.
DESCRIPTION
QTY.
1
300 psi/ 2000 kPa
Water Pressure Gauge
. .
2
2
1/4" Gauge Test Valve
. . 1
3
Model MC-1 Manual
Control Station
. . . . . . . . . 1
4
1-1/4" Angle Valve
. . . . . .
1
5
1/2" Ball Valve
. . . . . . . . .
2
6
1/2" Swing Check Valve
. .
1
7
1/2" Spring Loaded
Check Valve . . . . . . . . . .
1
8
Priming Supply
Restriction
. . . . . . . . . . . . 1
9
1/2" Y-Strainer
. . . . . . . . .
1
10
Model AD-1 Automatic
Drain Valve
. . . . . . . . . . .
1
11
Drip Funnel Connector
. .
1
12
Drip Funnel Bracket
. . . .
1
13
Drip Funnel
. . . . . . . . . . .
1
14
3/32" Vent Fitting
. . . . . . .
1
15
1/4" x 24" Tubing
. . . . . . .
1
16
1/2" Tubing Connector
. . 1
17
1/2" x 24" Tubing
. . . . . . .
1
18
1/4" Plug
. . . . . . . . . . . . . 1
19
3/4" Plug
. . . . . . . . . . . . .
1
20
1/2" x 1/4" Reducing
Bushing
. . . . . . . . . . . . . .
1
21
1/2" Union
. . . . . . . . . . . . 4
22
1/2" 90° Elbow
. . . . . . . . .
6
23
1/2" Tee
. . . . . . . . . . . . . .
5
24
1/2" x 1/4" x 1/2" Tee
. . . .
2
25
1/2" x 1/2" x 3/4" Tee
. . . .
1
26
1/2" x 1-1/2" Nipple
. . . . .
18
27
1/2" x 2" Nipple
. . . . . . . .
1
28
1/2" x 2-1/2" Nipple
. . . . . 1
29
1/2" x 3-1/2" Nipple
. . . . .
1
30
1/2" x 4-1/2" Nipple
. . . . .
1
31
1/4" x 3" Nipple
. . . . . . . .
1
32
1-1/4" x 3" Nipple
. . . . . . . 1
D1
Model DP-1
Dry Pilot Actuator
. .
1
52-280-1-001
D2
250 psi/ 1750 kPa
Air Pressure
Gauge
. . . . . . . . . . .
1
92-343-1-012
D3
1/4" Gauge Test
Valve
. . . . . . . . . . . .
1
46-005-1-002
D4
1/2" Globe Valve
. . .
1
46-047-1-004
D5
1/4" Pressure
Relief Valve
. . . . . . .
1
92-343-1-020
D6
1/4" Plug
. . . . . . . . .
1
CH
D7
1/2" Tubing
Connector
. . . . . . . .
1
CH
D8
1/2" x 24" Tubing
. .
1
CH
D9
1/2" 90° Elbow
. . . .
1
CH
D10
1/2" x 1/2" x 1/4"
Reducing Tee
. . . . .
2
CH
D11
1/2" Tee
. . . . . . . . .
2
CH
D12
1/4" x 1-1/2"
Nipple
. . . . . . . . . . .
1
CH
D13
1/2" x 1-1/2"
Nipple
. . . . . . . . . . .
6
CH
D14
1/2" x 2-1/2"
Nipple
. . . . . . . . . . .
1
CH
D15
1/2" x 5" Nipple
. . . .
1
CH
— EXPLODED VIEW OF DRY PILOT ACTUATION TRIM (52-445-2-102)—
P/N
92-343-1-005
46-005-1-002
LOW PRESSURE
52-289-2-001
ALARM SWITCH
46-048-1-007
(ORDERED
46-050-1-004
SEPARATELY)
46-049-1-004
92-322-1-002
92-020-1-009
52-353-1-005
52-793-2-004
92-211-1-005
92-211-1-003
92-343-1-007
92-032-1-002
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
1
CH
CH
CH
CH
CH
CH
CH
24
3
26
16
22
4
18
NOTES:
1.
Dry Pilot Actuation Trim is comprised
of Items 1-32 plus D1-D15.
2.
All Fittings and Nipples are
galvanized (Standard Order).
2-1/2 INCH (DN65) MODEL DV-3HP DELUGE VALVES
(Refer to Figure 12 to see the factory assembled trim segments,
as well as functional callouts of the trim components)
D13
D11
D15
D10
D12
D13
D1
D13
D13
D8
D14
D9
26
21
8
22
26
23
30
29
23
26
32
17
26
21
1
26
20
31
2
22
3.
CH: Common Hardware.
4.
See Figure 1 for Valve Port
identification.
5.
Route all Tubing to Drip Funnel.
FIGURE 6
D5
D10
D13
D11
D13
D4
D2
D3
D6
D9
D7
22
26
25
9
26
26
24
7
21
26
5
22
15
26
26
21
5
26
10
26
6
13
28
TFP1355
PRESSURE
ALARM SWITCH
(ORDERED
SEPARATELY)
19
LOCATION
FOR OPTIONAL
ELECTRICALLY
SUPERVISED
N.O. ALARM
CONTROL VALVE
(BVS-3/4")
14
(GREEN
TINT)
26
22
26
26
23
27
23
26
23
11
12