Prior to set up

Floor bearing capacity
Ensure that the substructure is capable of bearing the weight of the
stove prior to set-up�
Note
No modifications may be made to the firing installation� This also
leads to loss of warranty and guarantee�
Floor protection
A glass, sheet steel or ceramic plate is required, if the floor is
combustible (wood, carpet, etc�)�
Flue pipe connection
Flue pipes pose a particular source of hazard regarding gas leaks
Q
and fire� Get the advice of an authorised specialist company for
the layout and assembly�
Please observe the corresponding installation guidelines for walls
Q
panelled with wood when connecting your flue pipes to the stove�
Observe the formation of flue gas (atmospheric inversion) and
Q
draughts when the weather is unfavourable�
Infeed of too little combustion air can lead to smoke in the rooms
Q
or to flue gas leaks� Hazardous deposits in the stove and chimney
may also occur�
If flue gas escapes, let the fire burn out and check whether all the
Q
air inlet openings are free and the flue gas pipes and the stove
pipe are clean� If in doubt notify the master chimney sweep since
draught malfunctions may be connected to your chimney�
Stoves type 1 (BA 1):
Suitable for multiple occupancy� (Note the different country
Q
regulations�)
These may only be operated with the combustion chamber door
Q
closed�
The combustion chamber door may only be opened to add fuel
Q
and must then be closed again otherwise other firing installations
connected to the chimney may be endangered�
The combustion chamber door is to be kept closed when the
Q
stove is not in operation�
Fouling of the chimney i�e� deposits of highly inflammable
Q
materials such as soot and tar and subsequently fire in the
chimney may occur if wet fuel is used and operation is damped
too much�
If
this
occurs,
close
Q
regulator,
flaps
-
depending
the
mains
plug
at
Phone the fire brigade and get yourself and other residents out
of harm's way�
Note
on ROOM-AIR DEPENDENT and ROOM-AIR INDEPENDENT
OPERATION:
Your stove has been tested as a room-air independent stove
according to EN 13240 and can be installed as well room-air
dependent and independent�
When installed room-air dependent in combination with room-
air installations (e�g� controlled ventilation and venting systems
(extractors etc�) it must be ensured that the stove and the room
air system are monitored and safeguarded mutually (e�g� via a
differential pressure controller etc�)� The combustion air infeed of
approx� 20 m3/h must be ensured�
Please observe the respective local regulations and rules in
consultation with your master chimney sweep� For changes after
the printing of this manual, we can not assume any liability� We
reserve the right to change without notice�
the
fresh
air
support
on
model)!
Disconnect
the
stoves
type
Rikatronic�
8
(slider,
|9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rikatronic4

Table of Contents