3 - Description
Filters
A EasyClean suction filter is fitted in the working zone.
A Cyclone pressure filter is fitted to the sprayers right side just in front of the ChemLocker (optional equipment). It has a built-
in self-cleaning function.
In-line pressure filters can be fitted at each boom section as an option.
Nozzle filters are fitted at each nozzle.
All filters should always be in use and their function checked regularly. Pay attention to the correct combination of filter and
mesh size (see "Spray Technique" book).

EasyClean Filter

To ensure proper function of filter and its built-in valve the filter must be
opened at least once every month. A label on the lid also designates this.
• To open filter then turn it counterclockwise and pull it up, like
shown on picture.
• Pull out the two locks (A) to remove filter element from the lid.
Besides the spray pressure gauge on the platform an EasyClean
clogging indicator is located:
Clogging indicator colour
Green indicator.
Yellow indicator.
Red indicator.
18
Filter status
No cleaning necessary.
It is possible to finish an ongoing spraying job and
then clean filter afterwards.
Clean the EasyClean Filter immediately, as the filter is
clogged.