Input Conductors; Input Connection Procedure - ESAB ESP-400C Installation, Operation And Maintenance Manual

Plasma power source
Table of Contents

Advertisement

SECTION 3

3.4.2 Input Conductors

NOTICE

3.4.3 Input Connection Procedure

3
1
Primary Terminals
2
Chassis Ground
3
Power Input Cable Access Opening (Rear Panel)
3-4
Input conductors must be terminated with
ring terminals.
Input conductors must be terminated with ring
terminals sized for ½" hardware before being
attached to the ESP-400C.
1. Remove left side panel of the ESP-400C
2. Thread cables through the access opening in
3. Secure cables with a strain relief or conduit
4. Connect the ground lead to the stud on the
1
5. Connect the power lead ring terminals to the
2
6. Connect the input conductors to the line (wall)
ESP-400C Plasma Power Source
Customer supplied
May consist either of heavy rubber covered
copper conductors (three power and one
ground) or run in solid or flexible conduit.
Sized according to the chart.
the rear panel.
coupling (not supplied) at the access opening.
chassis base.
primary terminals with supplied bolts, washers
and nuts.
disconnect.
Installation