SECTION 3
3.5.2 Output Connection Procedure
3.6 Parallel Installation
CAUTION
3-6
Access Panel
1. Remove access panel on the lower front of the
power source.
2. Thread output cables through the openings at
the bottom of the front panel or at the bottom of
the power source immediately behind the front
panel.
3. Connect cables to designated terminals
mounted inside the power source using UL
listed pressure wire connectors.
4. Replace panel removed during the first step.
Two 400A power sources may be connected
together to extend the output current range.
Parallel power source start currents
exceed recommended amounts when
cutting below 100A.
Use Only One Power Source For Currents
Below 100A.
We recommend disconnecting the negative
lead from the secondary power source when
changing to currents below 100 amperes.
This lead should be safely terminated to
protect against electric shock.
ESP-400C Plasma Power Source
Installation