ESAB ESP-400C Installation, Operation And Maintenance Manual page 50

Plasma power source
Table of Contents

Advertisement

SECTION 6
Problem
Output current is unstable and
drifts above or below the setting.
6-12
Possible Cause
Place the PANEL/REMOTE
switch in the "PANEL" position.
Adjust current control pot. If
current no longer drifts, the
remote current control signal is
faulty.
Select "PANEL" on the
PANEL/REMOTE switch and
adjust the current control pot.
The current still drifts, measure
the current reference signal at
TB1-4 (+) and TB1-5 (-). If the
signal drifts, the current control
pot is faulty. If the signal does
not drift, the Control PCB (PCB1)
is faulty.
ESP 400C and 600C Plasma Power Sources
Troubleshooting
Action
Fix the remote current control
signal to operate the
PANEL/REMOTE switch in the
"PANEL" position.
Replace the current control pot.
Replace the control PCB (PCB1)
P/N 38032

Advertisement

Table of Contents
loading

This manual is also suitable for:

055800173005580017290558001731

Table of Contents