SECTION 3

3.4.2 Input Conductors

NOTICE

3.4.3 Input Connection Procedure

Power Input Cable
Access opening
(rear panel)
3-4
Primary
Terminals
Chassis Ground
ESP-600C Plasma Power Source
Customer supplied
May consist either of heavy rubber covered
copper conductors (three power and one
ground) or run in solid or flexible conduit.
Sized according to the chart.
Input conductors must be terminated with
ring terminals.
Input conductors must be terminated with ring
terminals sized for ½" hardware before being
attached to the ESP-600C.
1. Remove left side panel of the ESP-600C
2. Thread cables through the access opening in
the rear panel.
3. Secure cables with a strain relief or conduit
coupling (not supplied) at the access opening.
4. Connect the ground lead to the stud on the
chassis base.
5. Connect the power lead ring terminals to the
primary terminals with supplied bolts, washers
and nuts.
6. Connect the input conductors to the line (wall)
disconnect.
Installation