Ductwork Installation

Supply air duct connection is the responsibility of
the installer and should be installed per industry
best practices.
Supply discharge area is 8 1/16"D x 26 1/16"W.
Sheet metal or duct board may be used for the
transition from the discharge to 10" or larger
diameter flexible ducting.
Avoid sharp transitions in the ductwork to ensure
optimal indoor blower performance.
Allow at least 18" from the discharge of the unit
to the final reduced-size transition to support
optimal efficiency of the blower system.