  • Page 1 Ensto Wallbox Installation Instructions Operation Instructions RAK111_ENG 20.12.2019 © Ensto 2019...
  • Page 2: Table Of Contents

    11. Installation / Commissioning Checklist................24 12. Maintenance / Preventive Maintenance Instructions............ 25 13. RCD/MCB test instructions....................25 14. EVB100 Internal Circuit Example..................26 15. EVB101 Internal Circuit Example..................27 16. EVB200 Internal Circuit Example..................28 17. Extension Box EVK......................30 17.1.
  • Page 3: Ensto Wallbox

    1. Ensto Wallbox EVB100 / EVB103: Single charging unit (3-phase) EVB200: Dual charging unit (3-phase) EVB101: Single charging unit (1-phase) EVB201: Dual charging unit (1-phase) Ambient light Plastic front cover 3-color LED indicates the charging point’s status RFID reader Painted steel...
  • Page 4: Delivery Contains

    Flange KOT21715 Included in the delivery. Note! Cable glands are not included in the delivery. Please order suitable cable glands separately according to the used supply cable sizes, for example Ensto KTM... cable gland series (polyamide or brass). +0.1 -0.1 knock- outs RAK111_ENG / ©...
  • Page 5 EVTL40.00 Wall bracket The wall bracket is pre-installed to the charging station. 4x Ø7 2x Ø6 RAK111_ENG / © Ensto 2019...
  • Page 6 EVTL43.00 Ground / Floor mounting pole RAK111_ENG / © Ensto 2019...
  • Page 7 EVTL44.00 Adapter for ground mounting Ø54,5 Ø60,3 4 x M12 RAK111_ENG / © Ensto 2019...
  • Page 8 EVTL48.00 Wall mounting pole RAK111_ENG / © Ensto 2019...
  • Page 9: Mounting Instructions

    If the charging station is installed in conditions where there is a risk of metal rusting, vis- ible metal surfaces must be protected with anti-corrosion agent. min. 400 mm min. 200 mm Recommendation 1200 mm Follow always national regulations and site requirements RAK111_ENG / © Ensto 2019...
  • Page 10: Wall Mounting With Wall Bracket

    Open the front cover lock and remove the front cover. Note! RFID, LED module and antenna cables are attached to the front cover. Be careful not to break any components when you remove the front cover. RAK111_ENG / © Ensto 2019...
  • Page 11 Place the Wallbox on the wall bracket (1). Attach the top of the Wallbox on the wall bracket using the screws included in the delivery (2). Secure the bottom of the Wallbox with the screws included in the delivery (3). RAK111_ENG / © Ensto 2019...
  • Page 12: Ground Mounting On Concrete Casting With Ground Mounting Pole

    Fix the ground mounting pole on the anchor bolts with washers and nuts. Pull the electrical cables through the ground mounting pole. Attach the Wallbox on the mounting pole. See in- structions on page 16. RAK111_ENG / © Ensto 2019...
  • Page 13: Ground Mounting On Concrete Foundation With Ground Mounting Pole

    Fix the ground mounting pole on the adapter with bolts, washers and nuts. Pull the electrical cables through the ground mounting pole. 10. Attach the Wallbox on the mounting pole. See instructions on page 16. RAK111_ENG / © Ensto 2019...
  • Page 14: Wall Mounting On Wall Mounting Pole

    Adapter for 1 x EVB, product code US7650 1 pcs Adapter for 2 x EVB, product code US27657 1 pcs Note! When using the adapter for two Wallboxes (US27657), you can get up to four charging outlets. RAK111_ENG / © Ensto 2019...
  • Page 15 13. Fit the mounting pole to the threaded bolts on the adapter. Secure with the nuts included in the delivery. 14. Pull the electrical cables through the mounting pole. 15. Attach the Wallbox on the mounting pole. See instructions on page 16. RAK111_ENG / © Ensto 2019...
  • Page 16: Fixing Wallbox On Mounting Poles Evtl43.00 And Evtl48.00

    Open the knock-outs and insert the cable glands needed for electrical cables on flange KOT21715. Pull the electrical cables through the gable glands. Fix the Wallbox and flange KOT21715 on the mounting pole using the screws included in the delivery. RAK111_ENG / © Ensto 2019...
  • Page 17: Electrical Connections

    Ensure that the RFID, LED module and antenna cables are routed correctly. 10. Close the front cover. DC power supply Controller Supply board / boards connectors Cable route Plastic guide Front DIN rail Electrical cables RAK111_ENG / © Ensto 2019...
  • Page 18: Power Supply

    Connect separate supply cables for each charging outlet. Stranded cables are recommended in Wallbox installations. EVB100 and EVB200: A Residual current protection device (RCD) and a circuit breaker (MCB) for each charging outlet must be installed in the switchboard. EVB101/ EVB103 / EVB201 / EVB203: A combined RCD / MCB is integrated in the charging station.
  • Page 19 Example 2: Supply connection from IT network for Wallbox with 2 outlets SUPPLY 2 SUPPLY 1 Example 3: Supply connection for Wallbox with 1 outlet, integrated RCD / MCB SUPPLY RAK111_ENG / © Ensto 2019...
  • Page 20: Commissioning

    If you want to change the default settings, you must connect to Wallbox via web configuration tool to be able to proceed with the commissioning settings. Use Firefox or Windows Explorer web-browser for configuring. Micro USB service port Please see detailed commissioning instructions on https://evwiki.ensto.technology/ RAK111_ENG / © Ensto 2019...
  • Page 21: User Instructions

    When you stop the charging event, the indicator light turns to waving green and you are able to unplug the charging cable. • After you have unplugged, you are logged out from the charging point and the charging point is free for the next user. RAK111_ENG / © Ensto 2019...
  • Page 22: Technical Information - Evb

    3-color LED • Green / Ready • Blue / Charging • Red / Error) Use access RFID (ISO/IEC 14443A, ISO/IEC 15693) Free access Mobile apps via 3rd party operators Current measurement Integrated / on-board measurement RAK111_ENG / © Ensto 2019...
  • Page 23: Dimension Drawing

    Safety Features RCMB On-board: RCMB (6mA DC residual current detection) EVB100 / EVB200: To be located in distribution board (at least type A, 30mA) EVB100 / EVB200: To be located in distribution board (class C, nominal current 32A) RCB / MCB...
  • Page 24: Installation / Commissioning Checklist

    Test the function of the RCD / MCB. Depending on the charging station model, the device is integrated in the charging station or installed in the switchboard. Ready for Correct SW in use Correct operating mode • Standalone • Online RAK111_ENG / © Ensto 2019...
  • Page 25: Maintenance / Preventive Maintenance Instructions

    13. RCD/MCB test instructions Press the TEST button. • • The rocker turns to 0 position. • Turn the rocker back to I position. • If a fault occurs, contact an electrician. RAK111_ENG / © Ensto 2019...
  • Page 26: Evb100 Internal Circuit Example

    14. EVB100 Internal Circuit Example LED2 LED1 LED Board Antenna RFID RFID Board XST4003 XST1103 XST1200 XST4002 XST1102 XST1101 XST1100 RFID XST1201 XST9000 XBU1100 XBU1000 MINI USB RGB1 + WHITE GND IN XBU8001 XBU03000 12V IN RGB2 XBU8000 GND OUT...
  • Page 27: Evb101 Internal Circuit Example

    GND OUT ANTENNA 12V OUT EX OUT 2 EX OUT 2 IN AC Power IN AC TEST RESET IC11000 EX SOCKET XBU6000 CHAGO PE (M5) WALLBOX Controller XKL6000 XKL6001 XKL6002 BU/RD BU/BN BU/GN BU/YE TYPE2 SUPPLY RAK111_ENG / © Ensto 2019...
  • Page 28: Evb200 Internal Circuit Example

    GND IN XBU8001 IC11000 RGB1 + WHITE CHAG WALL Cont XBU1000 XBU1100 XKL6000 XST9000 XST1201 RFID XST1100 XST1101 XST1102 XST4002 XST1200 XST1103 XST4003 BU/RD BU/BN BU/GN BU/YE 6 7 8 9 10 Emergency Opener TYPE2 RAK111_ENG / © Ensto 2019...
  • Page 29 12V OUT EX OUT 2 EX OUT 2 TEST RESET EX SOCKET XBU6000 PE (M5) LBOX troller XKL6001 XKL6002 BU/RD BU/BN BU/GN BU/YE 6 7 8 9 10 Emergency Opener TYPE2 SUPPLY 1 SUPPLY 2 RAK111_ENG / © Ensto 2019...
  • Page 30: Extension Box Evk

    17. Extension Box EVK... The EVK... is designed as an extension box for EVB100 and EVB200. As default the extension box is provided with RCB/MCB (combined residual current protection device and a circuit breaker) and a MID class energy meter.
  • Page 31: Mounting The Extension Box

    Secure the lugs with the screws in- 90° cluded. You can put the fastening lugs in three possible positions. Prepare the wall for installation. Use screw type depending on the wall type. RAK111_ENG / © Ensto 2019...
  • Page 32: Wiring Instructions

    PE terminal on the extension box. Connect the extension box to the Wallbox, see wiring example on page 33. See also Wallbox wiring instructions on page 17. RAK111_ENG / © Ensto 2019...
  • Page 33 WARNING! Danger of electrical shock or injury. Always disconnect power before carrying out work on the device. XST1100 XST1101 XST1102 XST4002 XST1200 XST1103 XST4003 XST1100 XST1101 XST1102 XST4002 XST1200 XST1103 XST4003 L1 L2 L3 L1 L2 L3 RAK111_ENG / © Ensto 2019...
  • Page 34: Technical Information - Evk

    Dimensions 300 x 400 x 132 mm Weight approx. 4,1 kg, depends on product configuration Enclosure class IP66 Shock protection rate IK08 Operating temperature -25 °C … +65 °C Mounting On wall with fastening lugs RAK111_ENG / © Ensto 2019...
  • Page 35: Troubleshooting

    “Device Manager” that RNDIS tablished via web browser. network adapter is available. If not, update the related Windows driver. 19. Warranty Warranty conditions, see the product card on www.ensto.com. RAK111_ENG / © Ensto 2019...
  • Page 36 Ensto Finland Oy Ensio Miettisen katu 2, P.O. Box 77 FIN-06101 Porvoo, Finland Tel. +358 20 47 621 Customer service +358 200 29 007 ensto@ensto.com...

This manual is also suitable for:

Evb103Evb200Evb101Evb201

Table of Contents