Summary of Contents for ensto One Apartment EVH161-ACRM0

  • Page 1 Ensto One Apartment EVH161-ACRM0 EVH321-ACRM0 EVH161-A2RM0 EVH321-A2RM0 EVH161-A2RMD Installation Guide User Guide RAK132_ENG 1.9.2020 © Ensto 2020...
  • Page 2: Table Of Contents

    15. Troubleshooting....................19 16. Disposal......................19 17. Warranty......................19 18. Declaration of Conformity................19 19. Ensto Charger Control Application..............20 19.1. Installing the application..............20 19.2. Pairing the charger with your mobile device........21 19.3. Changing the maximum charging current......... 22 19.4.
  • Page 3: Installation Guide

    Do not switch on the power supply before the installation work is completed. 2. Delivery contents • EVH Charger • Cable gland M32/M25 (depending on the model) • Installation and User Guide in English, other languages please see www.ensto.com. • Multilingual Quick Guide RAK132_ENG / © Ensto 2020 3 / 28...
  • Page 4: Charger Features

    RFID reader 4-color LED indicates the charger’s status Mechanical hatch lock Mode 3, Type 2 socket with protective flap Fixed charging cable Mechanical hatch lock Domestic socket EVH161-A2RMD Separate charging cable, not included RAK132_ENG / © Ensto 2020 4 / 28...
  • Page 5: Mounting Instructions

    • The minimum space needed for operating and maintenance. min. 200 mm min. 200 mm Recommendation 900 - 1200 mm Follow always national regulations min. 500 mm and site requirements RAK132_ENG / © Ensto 2020 5 / 28...
  • Page 6: Cable Entries

    Remove the insert from the base. Installation box Base Remove the screws 2pcs. Remove the screws 4pcs. Remove the installation box cover. Unlock the hatch with a coin or suchlike. Installation box cover TX20 RAK132_ENG / © Ensto 2020 6 / 28...
  • Page 7 Black reduction nipple, M32 => M25 EVH161-A2RMD: included 1pc RGM16B Membrane gasket for cable Ø 5 - 9mm RMM25B Membrane gasket for cable Ø 8 - 17mm RMM32B Membrane gasket for cable Ø 12 - 24mm RAK132_ENG / © Ensto 2020 7 / 28...
  • Page 8: Wall Mounting

    Installation steps Use screw type depending on the wall material. Fasten the upper screw 1270 mm measured from the ground surface. The plug holder will be at a height of 1200 mm. RAK132_ENG / © Ensto 2020 8 / 28...
  • Page 9 Strip the leads 11 mm and connect to the supply connectors. 10. Put the installation box cover back in right position and secure with the screws you re- moved. 11. Close the installation box hatch. RAK132_ENG / © Ensto 2020 9 / 28...
  • Page 10: Power Supply

    Cu 2.5 - 10 mm² Cu 2.5 - 10 mm² A label set of RCBO testing instructions is included in the delivery. Attach a language specific label on the installation box hatch. RAK132_ENG / © Ensto 2020 10 / 28...
  • Page 11: Commissioning The Charger

    You can configurate charger’s settings in EV Manager. Please see the EV Manager User Manual https://evwiki.ensto.technology/display/CHWI/EV+Manager. You can also make changes to the settings with Ensto Charger Control Application. You can download the application from Google Play or App Store. Please see instructions in chapter 19.
  • Page 12: Technical Information

    Green = Ready / Blue = Charging / Red = Error / Yellow = SW update Free access Use access RFID (ISO/IEC 14443A, ISO/IEC 15693) Mobile application Current measure- MID class kWh meter ment *The charging cable is not included. RAK132_ENG / © Ensto 2020 12 / 28...
  • Page 13: Dimension Drawing

    Wireless Bluetooth Wired Ethernet “Simplified control pilot” functionality, specified in EN IEC 61851-1:2019, Charging control Annex A.2.3 is not supported. system ZEReady 1.2b and EVReady 1.4b are not supported. 8. Dimension drawing RAK132_ENG / © Ensto 2020 13 / 28...
  • Page 14: Installation / Commissioning Checklist

    Test the function of Mode 3 (from green to blue). Use a Mode 3 tester. Test the functionality of the residual current protection device. Ready for Correct software is in use. Correct operating mode. RAK132_ENG / © Ensto 2020 14 / 28...
  • Page 15: Maintenance / Preventive Maintenance Instructions

    Open the installation box hatch. Press the TEST button. • • The rocker turns to the 0 position. • Turn the rocker back to the I position. • If a fault occurs, contact an electrician. RAK132_ENG / © Ensto 2020 15 / 28...
  • Page 16: Evh161-Acrm0 / Evh321-Acrm0 Internal Circuit Example

    12. EVH161-ACRM0 / EVH321-ACRM0 internal circuit example Supply Note! All signal wires must be at a sufficient distance from the power wires or protected with insulating shield / plastic spiral. RAK132_ENG / © Ensto 2020 16 / 28...
  • Page 17: Evh161-A2Rm0 / Evh321-A2Rm0 Internal Circuit Example

    YE/BU RFID RFID Board A1 EVI200 6 7 8 Supply Note! All signal wires must be at a sufficient distance from the power wires or protected with insulating shield / plastic spiral. RAK132_ENG / © Ensto 2020 17 / 28...
  • Page 18: Evh161-A2Rmd Internal Circuit Example

    YE/BU RFID RFID Board A1 EVI200 6 7 8 Supply Note! All signal wires must be at a sufficient distance from the power wires or protected with insulating shield / plastic spiral. RAK132_ENG / © Ensto 2020 18 / 28...
  • Page 19: Troubleshooting

    Warranty conditions, see the product card on www.ensto.com. 18. Declaration of Conformity Hereby, Ensto Chago Oy declares that the Ensto One chargers are in compliance with Direc- tive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.ensto.com.
  • Page 20: Ensto Charger Control Application

    19. Ensto Charger Control Application • With the Ensto Charger Control Application (electrical) installator can control the charger and change the settings of the charger. • Bluetooth technology is used for the wireless connection. • You can pair your mobile device to several chargers, but it can be connected only to one charger at a time.
  • Page 21: Pairing The Charger With Your Mobile Device

    When the pairing is completed, you can find your charger in “My Devices”. If you want to control the charger with another mobile device, follow the pairing steps above. Note! The charger can be paired only to one mobile device at a time. RAK132_ENG / © Ensto 2020 21 / 28...
  • Page 22: Changing The Maximum Charging Current

    EVH161-ACRM0 / EVH161-A2RM0 / EVH161-A2RMD : 16A EVH132-ACRM0 / EVH132-A2RM0: 32A If the electric system dimensioning on the installation site requires a lower charging current than the charger’s nominal value, you can change the setting with the Ensto Charger Control application. •...
  • Page 23: Error Messages

    Switch off the charger from the main The charger has detected a short circuit switch and then switch it on again. If the in the charging cable. error occurs again, try charging with an- other charging cable. RAK132_ENG / © Ensto 2020 23 / 28...
  • Page 24 If the error occurs again, contact service. If you need to contact Ensto related to faulty operation of the charger, go first to “Support / Er- ror log”. Save the error log information before contacting. This information helps the technical support and maintenance to resolve the issue.
  • Page 25: User Guide

    User Guide 20. Introduction This User Guide is for the Ensto One Apartment Charger family. Even if the features and ap- pearance of the different charger versions varies, the usage of the product always follow the principles described in this guide. Available features depend on the charger model.
  • Page 26: Safety Instructions For User

    Your vehicle is connected, charging starts Blue Waving Charging ongoing Blue Stable Error state Stable Software update ongoing. Do not switch off the power or use the charger during Yellow Stable the update. RAK132_ENG / © Ensto 2020 26 / 28...
  • Page 27: Charging

    Plug in your electric vehicle. • The LED indicator turns to stable blue. Stop charging • Unplug your electric vehicle. • After you have unplugged the charger is free for the next user. RAK132_ENG / © Ensto 2020 27 / 28...
  • Page 28: Charging With Rfid

    Unplug the charging cable from the charger (EVH...-A2RM0 / EVH161-A2RMD). • Unplug the charging cable from the electric vehicle. The charger is free for the next user. Ensto Chago Oy Ensio Miettisen katu 2, P.O. Box 77 FIN-06101 Porvoo, Finland Tel. +358 20 47 621 Customer service +358 200 29 007 ensto@ensto.com...