Summary of Contents for ensto EVF100

  • Page 1 Ensto Pro EVF100 / EVF200 / EVF300 Installation instructions Operation instructions RAK112_ENG 21.5.2019 © Ensto 2019...
  • Page 2: Table Of Contents

    4. Accessories....................... 6 5. Mounting instructions..................... 11 5.1 Before Installation..................11 5.2 EVF100 / EVF200 mounting on concrete casting at site......12 5.3 EVF100 / EVF200 mounting on ground mounting frame......14 5.4 EVF100 / EVF200 mounting on concrete foundation....... 16 5.5 EVF100 / EVF200 mounting on Unimi concrete foundation....
  • Page 3: Evf100 / Evf200 / Evf300

    Ensto Pro 1. EVF100 / EVF200 / EVF300 Ensto Pro (EVF) is a solution for charging one or two electric vehicles. It is engineered especially for fast AC charging, but the station can be equipped also with domestic sockets. EVF100: Single charging station...
  • Page 4: Delivery Contains

    Accessories and site Ground mounting on Anchor bolts from a local supplier concrete at site Ground mounting on Concrete foundation, concrete foundation product code SJR-08 from Sähkö-Jokinen Oy, https://www.sahkojokinen. fi/en EVTL35.00: Ground mounting EVTL37.00: Adapter RAK112_ENG / © Ensto 2019...
  • Page 5 Ground mounting on From Unimi Solutions: from top Unimi concrete founda- Concrete foundation, product code 100-1 tion Cover plate Adapter, product code 100-13 www.unimi.se Wall mounting EVTL31.00: Wall installation kit including installation box and rail RAK112_ENG / © Ensto 2019...
  • Page 6: Accessories

    4. Accessories Order numbers and dimensions. Ground mounting box for EVF100 / EVF200 EVTL32.00 EVTL32.00 is a ground mounting box with cable entry from bottom. Cable entry Cable glands M40x1.5 Ground mounting box for EVF100 / EVF200 EVTL34.00 EVTL34.00 is a ground mounting box with cable entry from top.
  • Page 7 Ground mounting frame for EVF100 / EVF200 EVTL28.00 EVTL28.00 is a whole set as shown on the picture. Concrete foundation adapter for EVF100 / EVF200 EVTL36.00 The concrete foundation adapter is designed to be used with a concrete foundation, product code SJR-08, supplied by Sähkö-Jokinen Oy.
  • Page 8 EVF100 / EVF200 Wall Installation kit EVTL31.00 EVTL31.00 is a wall installation kit including installation box and rail. Cable glands M40x1.5 RAK112_ENG / © Ensto 2019...
  • Page 9 Mounting box for EVF300 EVTL35.00 EVTL35.00 is a ground mounting box with cable entry from bottom to the main board. Cable glands M40x1.5 RAK112_ENG / © Ensto 2019...
  • Page 10 If you want to use a foundation from another manufacturer, make sure that the foundation is compatible with the adapter. Washer Installation M12 DIN125 A2 plate Threaded bar Threaded bar M12x128 A4 M12x90 A4 Washer 13/37 DIN9021 A2 Hexagon nut M12 DIN934 A2 Tube Ø 133 505.4 RAK112_ENG / © Ensto 2019...
  • Page 11: Mounting Instructions

    Remove the package around the charging station. Remove the film protecting the metal parts only after the installation is finished. Note! When selecting the installation location, take into consideration the minimum space needed for operat- ing and maintenance. EVF100 / EVF200 EVF300 RAK112_ENG / © Ensto 2019...
  • Page 12: Evf100 / Evf200 Mounting On Concrete Casting At Site

    5.2 EVF100 / EVF200 mounting on concrete casting at site Items needed: Ground mounting box EVTL32.00 / EVTL34.00 1 pcs Anchor bolts M12 4 pcs Washers Nuts Make sure that the materials used for the concrete foundation and the installation procedures follow local building regulations and safety standards.
  • Page 13 Strip the supply cable conductors 25 mm. Connect the supply cable wires to the supply terminal blocks. Ensure that the PE is connected to the EVF. Switch on F0, F1, F2 (if present) and QF1. Close the maintenance door. RAK112_ENG / © Ensto 2019...
  • Page 14: Evf100 / Evf200 Mounting On Ground Mounting Frame

    5.3 EVF100 / EVF200 mounting on ground mounting frame Items needed: Ground mounting frame EVTL28.00 1 pcs Ground mounting box EVTL32.00 / EVTL34.00 1 pcs Make sure that the materials used for the concrete foundation and the installation procedures follow local building regulations and safety standards.
  • Page 15 M12 Threaded bar Ground mounting box EVTL32.00 or EVTL34.00 Ground level Ground mounting frame EVTL28.00 Concrete Cable protection pipe ~500 RAK112_ENG / © Ensto 2019...
  • Page 16: Evf100 / Evf200 Mounting On Concrete Foundation

    5.4 EVF100 / EVF200 mounting on concrete foundation Items needed: Ground mounting box EVTL32.00 / EVTL34.00 1 pcs Adapter for concrete foundation EVTL36.00 1 pcs Concrete foundation 1 pcs This example describes installation procedure using concrete foundation, product code SJR-08, supplied by Sähkö-Jokinen Oy.
  • Page 17 Adapter EVTL36.00 Concrete foundation Cable protection pipe Ø110 Gravel RAK112_ENG / © Ensto 2019...
  • Page 18: Evf100 / Evf200 Mounting On Unimi Concrete Foundation

    5.5 EVF100 / EVF200 mounting on Unimi concrete foundation This example describes installation procedure using a concrete foundation supplied by Unimi Solutions. Items needed: Ground mounting box EVTL32.00 / EVTL34.00 1 pcs Please order the following items from www.unimi.se Concrete foundation Ensto Pro, product code 100-1...
  • Page 19 Connect the supply cable wires to the supply ter- minal blocks. • Ensure that the PE is connected to the EVF. • Switch on F0, F1, F2 (if present) and QF1. • Close the maintenance door. RAK112_ENG / © Ensto 2019...
  • Page 20: Evf100 / Evf200 Wall Mounting

    5.6 EVF100 / EVF200 wall mounting Items needed: Wall mounting kit EVTL31.00 1 pcs Screws or bolts Washers Nuts Installation steps Ensure that the wall is robust and stable. The mounting surface must be flat and vertical. Prepare the wall for installation and select the screw / bolt type depending on the wall type. Excercise extreme caution when drilling holes in the wall.
  • Page 21 Install to wall with 6 pcs hole screws / bolts Ø 16 Mounting box Bolt the EVF on Remove the cable sheath the mounting box beginning from the cable gland exit Supply cable direction RAK112_ENG / © Ensto 2019...
  • Page 22: Evf300 Mounting On Concrete Casting At Site

    Use the ground mounting box as a jig. Put the anchor bolts in place and tighten the anchor bolt nuts. Adjust nuts and washers on the anchor bolts horizontally. Place the ground mounting box on the concrete. RAK112_ENG / © Ensto 2019...
  • Page 23 Pull electrical cables through the ground mounting box cable gland(s) approx. 450 mm measured from the upper surface of the mounting box. Tighten the cable gland. Close the unused cable entries with cable gland plugs. Concrete Anchor bolt RAK112_ENG / © Ensto 2019...
  • Page 24 Install the second charging point module accordingly. Secure the top cover plate on the charging point and distribution cabinet modules with the washer and screw included in the delivery. Close the maintenance doors. Top cover plate RAK112_ENG / © Ensto 2019...
  • Page 25: Evf300 Mounting On Concrete Foundation

    The pit floor should be trampled and horizontal. • Fill the pit with gravel. Trample the filling around the foundation to ensure stability. Ground Adapter EVTL37.00 Cable protection pipe Ø110 Concrete foundation Gravel RAK112_ENG / © Ensto 2019...
  • Page 26 Install the second charging point module accordingly. Secure the top cover plate on the charging point and distribution cabinet modules with the washer and screw included in the delivery. Close the maintenance doors. Top cover plate RAK112_ENG / © Ensto 2019...
  • Page 27: Supply Connections

    System dimensioning must be done by a qualified electrical designer. EVF200 Possible supply connections: • Use separate supply cables for each charging point • Use one supply cable and chain internally to the charging points L1 L2 RAK112_ENG / © Ensto 2019...
  • Page 28 CHARGING POINT 2 NOTE! If phase rotation is needed, it can be carried out with charging point 1 and 2 supply terminals (L1, L2, L3). The phase rotation should be done in accordance to the electrical plan. RAK112_ENG / © Ensto 2019...
  • Page 29: Commissioning

    Insert the USB cable so that the longer edge of the facing is away from you. Do not remove any existing USB devices from any of the controller units! Please see detailed commissioning instructions on https://evwiki.ensto.technology/ RAK112_ENG / © Ensto 2019...
  • Page 30: User Instructions

    When you stop the charging event, the indicator light turns to waving green and you are able to unplug the charging cable. • After you have unplugged, you are logged out from the charging point and the charging point is free for the next user. RAK112_ENG / © Ensto 2019...
  • Page 31: Technical Data

    Type B (6mA DC) Low control voltage Default 12 VDC Optional features RCD autoreset RCD remote test Surge, overvoltage protection Automatic release for Mode 3 socket in case of sudden power outage Temperature sensor Tilt sensor RAK112_ENG / © Ensto 2019...
  • Page 32 A remotely read kWh me- ter installed in the station by an electricity company Connectivity and EVF100 EVF200 EVF300 communication Connectivity Default: GSM (3G, 4G) Optional: Ethernet, Wifi Communication Default: OCPP 1.5 or OCPP1.6, both fully implemented RAK112_ENG / © Ensto 2019...
  • Page 33: Dimension Drawings

    10. Dimension Drawings EVF100 Ensto Pro with one charging point. The charging point is placed on the left side seen from the maintenance door. Note! Domestic socket is optional. RAK112_ENG / © Ensto 2019...
  • Page 34 EVF200 Ensto Pro with two charging points. Note! Domestic sockets are optional. RAK112_ENG / © Ensto 2019...
  • Page 35 EVF300 Ensto Pro with two charging points and a distribution cabinet. Note! Domestic sockets are optional. Distribution cabinet depth 160 mm Mounting plate inside the cabinet width 350 mm height 1250 mm RAK112_ENG / © Ensto 2019...
  • Page 36: Installation / Commissioning Checklist

    Verify that when charging point’s LED is green, there is no power at the socket con- tact (L1, L2, L3, N). Test the functioning of Mode 3; LED colors from green to blue. Use Mode 3 tester. RAK112_ENG / © Ensto 2019...
  • Page 37: Maintenance / Preventive Maintenance Instructions

    Test PE conductor resistance, must be less than 3 Ω. Test the surge arrester, if there is any. SW update if needed (if in service contract). Restart the station from F0, ensure it will restart properly. Maintenance performed by: Date: RAK112_ENG / © Ensto 2019...
  • Page 38: Evf100 Internal Wiring Diagram Example

    13. EVF100 Internal Wiring Diagram Example EVF100 has one insert. EVF200 and EVF300 have two identical inserts, one per charging point. A USB cable is connected between the controllers. OPTION Push Button Start Lock Magnet Supply L N I L1 L2 L3...
  • Page 39 Emergency IN AC Opener DIODE Power IN AC TEST RESET IC11000 EX SOCKET XBU6000 CHAGO PE (M5) WALLBOX Controller XKL6000 XKL6001 XKL6002 TYPE3 LED2 LED1 LED Board RFID RFID Board Ethernet OPTION USB to Ethernet RAK112_ENG / © Ensto 2019...
  • Page 40: Troubleshooting

    If not, update the related Windows driver. 15. Warranty Warranty conditions, see the product card on www.ensto.com Ensto Finland Oy Ensio Miettisen katu 2, P.O. Box 77 FIN-06101 Porvoo, Finland Tel. +358 20 47 621 Customer service +358 200 29 007...