SureCross DX80 Node with Discrete I/O
Configurable Node with eight discrete inputs and four discrete outputs
IP20 Base
900 MHz
For additional information, updated documentation, and accessories, refer to Banner Engineering's website,
ing.com/surecross.
Models
Frequency
DX80N9X6S8P4
900 MHz ISM Band
DX80N2X6S8P4
2.4 GHz ISM Band
DX80N9X6S8P4C
900 MHz ISM Band
DX80N2X6S8P4C
2.4 GHz ISM Band
Internal antenna models are also available, but are not UL Listed. For more information, contact your local Banner Engineering Corp.
representative.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
SureCross User Configuration Tool
P/N 132160 rev. H
The SureCross® wireless system is a radio frequency network with integrated I/O that
can operate in most environments and eliminate the need for wiring runs. Wireless net-
works are formed around a Gateway, which acts as the wireless network master device,
and one or more Nodes.
• Wireless industrial I/O device with eight selectable discrete inputs and four sourcing
discrete outputs
• 10 to 30V dc power input
• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple
IP67 Base
2.4 GHz
Access (TDMA) control architecture ensure reliable data delivery within the unlicensed
Industrial, Scientific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node, in-
cluding fully acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
• The DX80...C models are certified for use in Class I, Division 2, Group A, B, C, D;
Zone 2 (Category 3G) Hazardous Locations when properly installed in accordance
with the National Electrical Code, the Canadian Electrical Code, or applicable local co-
des/regulations (see Specifications)
Environmental Rating
IP67, NEMA 6
IP20, NEMA 1
Class I, Division 2, Group A, B, C,
D Hazardous Locations (see Speci-
fications)
The User Configuration Tool (UCT) offers an easy way to link I/O points in your wire-
less network, view I/O register values graphically, and set system communication pa-
rameters when a host system is not part of the wireless network.
The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt
radios, BWA-HW-006 can be used for all other radios) converter cable to pass infor-
mation between your computer and the Gateway. Download the most recent revi-
sions of the UCT software from Banner Engineering's website:
gineering.com/wireless.
5/21/2013
www.bannerengineer-
I/O
Inputs: Eight selectable discrete
Outputs: Four sourcing discrete
(When your wireless network does not include a
host system, the eight input/four output Node must
be mapped to the four input/eight output Gateway.)
http://www.banneren-
0 132160